![]() | Caution - This procedure requires that you handle components that are sensitive to static discharge, which can cause the component to fail. To avoid damage, wear an antistatic wrist strap and use an antistatic mat when handling components. |
To identify a specific memory module that has faulted, you must open the
storage controller and use the amber status LEDs on the motherboard. To identify
a general memory fault, go to the Maintenance > Hardware screen of the BUI,
and click on the right-arrow icon
on the controller. Then click DIMMs to locate the faulted
component, indicated by the warning icon
.
![]() | Caution - Because 3.3 VDC standby power is always present in the system, you must unplug the power cords before accessing any cold-serviceable components. |
The following illustration shows the Fault remind button on the 7120 controller.
The following illustration shows the Fault remind button on the 7420 controller.
The following image shows the 7420 chassis.
The Power/OK status indicator next to the Power button lights and remains lit.
for the controller and then click DIMM to verify that
the online icon
is green for the newly installed DIMM.