Replacing the SPM is a cold-service procedure that must be performed by qualified service personnel. The server must be completely powered down before performing this procedure.
Caution - Ensure that all power is removed from the server before working with the motherboard assembly. You must disconnect the power cables from the server before performing these procedures. |
Caution - This procedure requires that you handle components that are sensitive to electrostatic discharge. Static discharges can cause the components to fail. |
The SP OK indicator on the front panel will be off when an SPM fault is detected.
At the Oracle ILOM prompt, type:
-> cd /SP/config -> dump -destination uritarget
where acceptable values for uri are: tftp, ftp, sftp, scp, http, https
and target is the location where you want to store the configuration information. For example:
-> dump -destination tftp://129.99.99.99/pathname
See Install the SPM.