Set Power Supply Redundancy Policy on CMM

image:Icon for Oracle ILOM

You can prevent the Oracle blade chassis system from losing power in the event of a power supply failure by setting a Power Supply Redundancy Policy.

Before You Begin

This procedure provides both web and command-line interface (CLI) instructions for the chassis monitoring module (CMM).

  • To define the power supply redundancy policy in an Oracle blade chassis system:
    • From the Web interface:
      1. Click Power Management > Redundancy.
      2. Enable one of these options for the power supply redundancy policy: N+N (default) or None
      3. Click Save to apply your changes.
    • From the CLI, type:

      set /CMM/powermgmt redundancy=[ redundancy|none ]

See Also