Connector Locations

The InfiniBand (IB) fabric connects together the IB switches and the servers listed below in Oracle SuperCluster T5-8. For IB cable information, see Identifying InfiniBand Fabric Connections.

The Ethernet Management Switch also connects to the servers listed below. For 1 Gb/s Cat 5E cabling information, see Ethernet Management Switch Connections.

The following figures are in this section:

  • Sun Datacenter InfiniBand Switch 36 (Figure 24):

    • IB Spine Switch (slot U1)

    • IB Leaf Switch No. 1 (slot U26)

    • IB Leaf Switch No. 2 (slot U32)

  • SPARC T5-8 servers (Figure 25, Figure 26, and Figure 27):

    • SPARC T5-8 No. 1 (slot 10)

    • SPARC T5-8 No. 2 (slot 18)

  • ZFS storage controllers (Figure 28):

    • ZFS storage controller No. 1 (slot 33)

    • ZFS storage controller No. 2 (slot 34)

  • Exadata Storage Servers (Figure 29):

    • Exadata Storage Server No. 1 (slot 2)

    • Exadata Storage Server No. 2 (slot 4)

    • Exadata Storage Server No. 3 (slot 6)

    • Exadata Storage Server No. 4 (slot 8)

    • Exadata Storage Server No. 5 (slot 35) (Full Rack only)

    • Exadata Storage Server No. 6 (slot 37) (Full Rack only)

    • Exadata Storage Server No. 7 (slot 39) (Full Rack only)

    • Exadata Storage Server No. 8 (slot 41) (Full Rack only)

  • The Ethernet Management Switch (Figure 30)

  • PDU circuit breakers and AC sockets (Figure 31)

Figure 24  Sun Datacenter InfiniBand Switch 36

image:shows ports on the Sun Datacenter InfiniBand Switch 36.

Figure Legend

1 NET MGT 0 and NET MGT 1 ports

2InfiniBand ports 0A-17A (upper ports)

3InfiniBand ports 0B-17B (lower ports)



Figure 25  SPARC T5-8 Server Card Locations (Full Rack)

image:showing the card and port locations on the SPARC T5-8 server in a Full Rack.

Figure Legend

1 Dual-port 10 GbE network interface cards, for connection to the 10 GbE client access network

2Dual-port InfiniBand host channel adapters, for connection to the InfiniBand network



Figure 26  SPARC T5-8 Server Card Locations (Half Rack)

image:showing the card and port locations on the SPARC T5-8 server in a Half Rack.

Figure Legend

1 Dual-port 10 GbE network interface cards, for connection to the 10 GbE client access network

2Dual-port InfiniBand host channel adapters, for connection to the InfiniBand network



Figure 27  NET MGT and NET0-3 Port Locations on the SPARC T5-8 Server

image:showing the NET MGT and NET0-3 port locations on the SPARC T5-8 server.

Figure Legend

1 NET MGT port, for connection to Oracle ILOM management network

2NET0-NET3 ports, for connection to 1 GbE host management network



Figure 28  ZFS Storage Controller

image:shows locations of PCIe slots on the rear of the ZFS storage controller.

Figure Legend

1 Power supply 1

2Power supply 2

3System status LEDs

4Serial management port

5Service processor network management port

6Gigabit Ethernet ports NET 0, 1, 2, 3

7USB ports 0, 1

8HD15 video connector



Figure 29  Exadata Storage Server

image:shows location of ports on the rear of the Exadata Storage Server.

Figure Legend

1 Power supply 1

2Power supply 2

3System status LEDs

4Serial management port

5Service processor network management port

6Gigabit Ethernet ports NET 0, 1, 2, 3

7USB ports 0, 1

8HD15 video connector



Figure 30  Ethernet Management Switch (Cisco Catalyst 4948 Ethernet Switch)

image:shows port numbering for the Cisco Catalyst 4948 Ethernet switch

Figure Legend

1 Indicators and reset switch

2Ports 1-16, 10/100/1000BASE-T Ethernet

3Ports 17-32, 10/100/1000BASE-T Ethernet

4Ports 33-48, 10/100/1000BASE-T Ethernet

5CON (upper), MGT (lower)

6Ports 45-48, 10-Gigabit Ethernet



Figure 31  Circuit Breakers and AC Sockets on the PDU

image:shows the AC sockets.

Figure Legend

1 PDU A

2PDU B