Go to main content

Oracle® SuperCluster M8 and SuperCluster M7 Installation Guide

Exit Print View

Updated: January 2019
 
 

Leaf Switch Cabling (Single Server)

These two IB switches are factory installed and cabled:

  • Leaf switch 1 in U18

  • Leaf switch 2 in U24

image:A figure showing the IB switch connections.

This table lists the factory cable connections for leaf switch 1 and 2 for single-server configurations.

The table includes connections for the maximum number of CMIOUs and storage servers (11), but not all SuperCluster M8 or SuperCluster M7 models contain the maximum number of CMIOUs and storage servers.

From
To
Location
To
Component
To
Port
U18 (Leaf 1)
0A
0B
1A
1B
2A
2B
3A
U27
Storage server 11
PCIe 3, P1
3B
4A
U8
Compute server 0, CMIOU 6
P1
4B
U8
Compute server 0, CMIOU 7
P1
5A
U8
Compute server 0, CMIOU 4
P1
5B
U8
Compute server 0, CMIOU 5
P1
6A
U8
Compute server 0, CMIOU 2
P1
6B
U8
Compute server 0, CMIOU 3
P1
7A
U8
Compute server 0, CMIOU 0
P1
7B
U8
Compute server 0, CMIOU 1
P1
8A
U24
IB leaf switch 2
8A
8B
U1
IB spine switch (if present)
1B
9A
U24
IB leaf switch 2
9B
9B
U24
IB leaf switch 2
9A
10A
U24
IB leaf switch 2
10B
10B
U24
IB leaf switch 2
10A
11A
U24
IB leaf switch 2
11B
11B
U24
IB leaf switch 2
11A
12A
U26
ZFS storage controller 2
PCIe 0, P2
12B
U25
ZFS storage controller 1
PCIe 0, P1
13A
U31
Storage server 9
PCIe 3, P1
13B
U29
Storage server 10
PCIe 3, P2
14A
U33
Storage server 8
PCIe 3, P2
14B
U35
Storage server 7
PCIe 3, P1
15A
U39
Storage server 5
PCIe 3, P1
15B
U37
Storage server 6
PCIe 3, P2
16A
U41
Storage server 4
PCIe 3, P2
16B
U6
Storage server 3
PCIe 3, P1
17A
U2
Storage server 1
PCIe 3, P1
17B
U4
Storage server 2
PCIe 3, P2
U24 (Leaf 2)
0A
0B
1A
1B
2A
2B
3A
U27
Storage server 11
PCIe 3, P2
3B
4A
U8
Compute server 0, CMIOU 6
P2
4B
U8
Compute server 0, CMIOU 7
P2
5A
U8
Compute server 0, CMIOU 4
P2
5B
U8
Compute server 0, CMIOU 5
P2
6A
U8
Compute server 0, CMIOU 2
P2
6B
U8
Compute server 0, CMIOU 3
P2
7A
U8
Compute server 0, CMIOU 0
P2
7B
U8
Compute server 0, CMIOU 1
P2
8A
U18
IB leaf switch 1
8A
8B
U1
IB spine switch (if present)
0B
9A
U18
IB leaf switch 1
9B
9B
U18
IB leaf switch 1
9A
10A
U18
IB leaf switch 1
10B
10B
U18
IB leaf switch 1
10A
11A
U18
IB leaf switch 1
11B
11B
U18
IB leaf switch 1
11A
12A
U26
ZFS storage controller 2
PCIe 0, P1
12B
U25
ZFS storage controller 1
PCIe 0, P2
13A
U31
Storage server 9
PCIe 3, P2
13B
U29
Storage server 10
PCIe 3, P1
14A
U33
Storage server 8
PCIe 3, P1
14B
U35
Storage server 7
PCIe 3, P2
15A
U39
Storage server 5
PCIe 3, P2
15B
U37
Storage server 6
PCIe 3, P1
16A
U41
Storage server 4
PCIe 3, P1
16B
U6
Storage server 3
PCIe 3, P2
17A
U2
Storage server 1
PCIe 3, P2
17B
U4
Storage server 2
PCIe 3, P1

Related Information