Six-Rack
Cabling
This table shows the cable connections for the first spine
switch (R1-U1) when cabling six full racks together.
Table 44 Leaf Switch Connections for the First Rack in a Six-Rack
System
|
|
|
R1 U24 within Rack 1 |
R1-U24-P8A to R1-U1-P3A
R1-U24-P8B to R1-U1-P4A |
3m |
R1 U24 to Rack 2 |
R1-U24-P9A to R2-U1-P5A
R1-U24-P9B to R2-U1-P6A |
5m |
R1 U24 to Rack 3 |
R1-U24-P10A to R3-U1-P7A |
5m |
R1 U24 to Rack 4 |
R1-U24-P10B to R4-U1-P8A |
10m |
R1 U24 to Rack 5 |
R1-U24-P11A to R5-U1-P9A |
10m |
R1 U24 to Rack 6 |
R1-U24-P11B to R6-U1-P10A |
10m |
R1 U18 within Rack 1 |
R1-U18-P8A to R1-U1-P3B
R1-U18-P8B to R1-U1-P4B |
3m |
R1 U18 to Rack 2 |
R1-U18-P9A to R2-U1-P5B
R1-U18-P9B to R2-U1-P6B |
5m |
R1 U18 to Rack 3 |
R1-U18-P10A to R3-U1-P7B |
5m |
R1 U18 to Rack 4 |
R1-U18-P10B to R4-U1-P8B |
10m |
R1 U18 to Rack 5 |
R1-U18-P11A to R5-U1-P9B |
10m |
R1 U18 to Rack 6 |
R1-U18-P11B to R6-U1-P10B |
10m |
|
This table shows the cable connections for the second spine
switch (R2-U1) when cabling six full racks together.
Table 45 Leaf Switch Connections for the Second Rack in a Six-Rack
System
|
|
|
R2 U24 within Rack 2 |
R2-U24-P8A to R2-U1-P3A
R2-U24-P8B to R2-U1-P4A |
3m |
R2 U24 to Rack 1 |
R2-U24-P11B to R1-U1-P10A |
5m |
R2 U24 to Rack 3 |
R2-U24-P9A to R3-U1-P5A
R2-U24-P9B to R3-U1-P6A |
5m |
R2 U24 to Rack 4 |
R2-U24-P10A to R4-U1-P7A |
5m |
R2 U24 to Rack 5 |
R2-U24-P10B to R5-U1-P8A |
10m |
R2 U24 to Rack 6 |
R2-U24-P11Ato R6-U1-P9A |
10m |
R2 U18 within Rack 2 |
R2-U18-P8A to R2-U1-P3B
R2-U18-P8B to R2-U1-P4B |
3m |
R2 U18 to Rack 1 |
R2-U18-P11B to R1-U1-P10B |
5m |
R2 U18 to Rack 3 |
R2-U18-P9A to R3-U1-P5B
R2-U18-P9B to R3-U1-P6B |
5m |
R2 U18 to Rack 4 |
R2-U18-P10A to R4-U1-P7B |
5m |
R2 U18 to Rack 5 |
R2-U18-P10B to R5-U1-P8B |
10m |
R2 U18 to Rack 6 |
R2-U18-P11Ato R6-U1-P9B |
10m |
|
This table shows the cable connections for the third spine
switch (R3-U1) when cabling six full racks together.
Table 46 Leaf Switch Connections for the Third Rack in a Six-Rack
System
|
|
|
R3 U24 within Rack 3 |
R3-U24-P8A to R3-U1-P3A
R3-U24-P8B to R3-U1-P4A |
3m |
R3 U24 to Rack 1 |
R3-U24-P11A to R1-U1-P9A |
5m |
R3 U24 to Rack 2 |
R3-U24-P11B to R2-U1-P10A |
5m |
R3 U24 to Rack 4 |
R3-U24-P9A to R4-U1-P5A
R3-U24-P9B to R4-U1-P6A |
5m |
R3 U24 to Rack 5 |
R3-U24-P10A to R5-U1-P7A |
5m |
R3 U24 to Rack 6 |
R3-U24-P10B to R6-U1-P8A |
5m |
R3 U18 within Rack 3 |
R3-U18-P8A to R3-U1-P3B
R3-U18-P8B to R3-U1-P4B |
3m |
R3 U18 to Rack 1 |
R3-U18-P11A to R1-U1-P9B |
5m |
R3 U18 to Rack 2 |
R3-U18-P11B to R2-U1-P10B |
5m |
R3 U18 to Rack 4 |
R3-U18-P9A to R4-U1-P5B
R3-U18-P9B to R4-U1-P6B |
5m |
R3 U18 to Rack 5 |
R3-U18-P10A to R5-U1-P7B |
5m |
R3 U18 to Rack 6 |
R3-U18-P10B to R6-U1-P8B |
5m |
|
This table shows the cable connections for the fourth spine
switch (R4-U1) when cabling six full racks together.
Table 47 Leaf Switch Connections for the Fourth Rack in a Six-Rack
System
|
|
|
R4 U24 within Rack 4 |
R4-U24-P8A to R4-U1-P3A
R4-U24-P8B to R4-U1-P4A |
3m |
R4 U24 to Rack 1 |
R4-U24-P10B to R1-U1-P8A |
10m |
R4 U24 to Rack 2 |
R4-U24-P11A to R2-U1-P9A |
5m |
R4 U24 to Rack 3 |
R4-U24-P11B to R3-U1-P10A |
5m |
R4 U24 to Rack 5 |
R4-U24-P9A to R5-U1-P5A
R4-U24-P9B to R5-U1-P6A |
5m |
R4 U24 to Rack 6 |
R4-U24-P10A to R6-U1-P7A |
5m |
R4 U18 within Rack 4 |
R4-U18-P8A to R4-U1-P3B
R4-U18-P8B to R4-U1-P4B |
3m |
R4 U18 to Rack 1 |
R4-U18-P10B to R1-U1-P8B |
10m |
R4 U18 to Rack 2 |
R4-U18-P11A to R2-U1-P9B |
5m |
R4 U18 to Rack 3 |
R4-U18-P11B to R3-U1-P10B |
5m |
R4 U18 to Rack 5 |
R4-U18-P9A to R5-U1-P5B
R4-U18-P9B to R5-U1-P6B |
5m |
R4 U18 to Rack 6 |
R4-U18-P10A to R6-U1-P7B |
5m |
|
This table shows the cable connections for the fifth spine
switch (R5-U1) when cabling six full racks together.
Table 48 Leaf Switch Connections for the Fifth Rack in a Six-Rack
System
|
|
|
R5 U24 within Rack 5 |
R5-U24-P8A to R5-U1-P3A
R5-U24-P8B to R5-U1-P4A |
3m |
R5 U24 to Rack 1 |
R5-U24-P10A to R1-U1-P7A |
10m |
R5 U24 to Rack 2 |
R5-U24-P10B to R2-U1-P8A |
10m |
R5 U24 to Rack 3 |
R5-U24-P11A to R3-U1-P9A |
5m |
R5 U24 to Rack 4 |
R5-U24-P11B to R4-U1-P10A |
5m |
R5 U24 to Rack 6 |
R5-U24-P9A to R6-U1-P5A
R5-U24-P9B to R6-U1-P6A |
5m |
R5 U18 within Rack 5 |
R5-U18-P8A to R5-U1-P3B
R5-U18-P8B to R5-U1-P4B |
3m |
R5 U18 to Rack 1 |
R5-U18-P10A to R1-U1-P7B |
10m |
R5 U18 to Rack 2 |
R5-U18-P10B to R2-U1-P8B |
10m |
R5 U18 to Rack 3 |
R5-U18-P11A to R3-U1-P9B |
5m |
R5 U18 to Rack 4 |
R5-U18-P11B to R4-U1-P10B |
5m |
R5 U18 to Rack 6 |
R5-U18-P9A to R6-U1-P5B
R5-U18-P9B to R6-U1-P6B |
5m |
|
This table shows the cable connections for the sixth spine
switch (R6-U1) when cabling six full racks together.
Table 49 Leaf Switch Connections for the Sixth Rack in a Six-Rack
System
|
|
|
R6 U24 within Rack 6 |
R6-U24-P8A to R6-U1-P3A
R6-U24-P8B to R6-U1-P4A |
3m |
R6 U24 to Rack 1 |
R6-U24-P9A to R1-U1-P5A
R6-U24-P9B to R1-U1-P6A |
10m |
R6 U24 to Rack 2 |
R6-U24-P10A to R2-U1-P7A |
10m |
R6 U24 to Rack 3 |
R6-U24-P10B to R3-U1-P8A |
5m |
R6 U24 to Rack 4 |
R6-U24-P11A to R4-U1-P9A |
5m |
R6 U24 to Rack 5 |
R6-U24-P11B to R5-U1-P10A |
5m |
R6 U18 within Rack 6 |
R6-U18-P8A to R6-U1-P3B
R6-U18-P8B to R6-U1-P4B |
3m |
R6 U18 to Rack 2 |
R6-U18-P10A to R2-U1-P7B |
10m |
R6 U18 to Rack 1 |
R6-U18-P9A to R1-U1-P5B
R6-U18-P9B to R1-U1-P6B |
10m |
R6 U18 to Rack 3 |
R6-U18-P10B to R3-U1-P8B |
5m |
R6 U18 to Rack 4 |
R6-U18-P11A to R4-U1-P9B |
5m |
R6 U18 to Rack 5 |
R6-U18-P11B to R5-U1-P10B |
5m |
|