Go to main content

Oracle® SuperCluster M8 and SuperCluster M7 Installation Guide

Exit Print View

Updated: January 2019
 
 

Ethernet Management Switch Cabling Reference

The Ethernet management switch is located in U19 and is factory cabled.

image:Figure shows port numbering for the Ethernet management switch
No.
Description
No.
Description
1
Indicators and reset switch
4
Ports 33-48, 10/100/1000BASE-T Ethernet
2
Ports 1 to 16, 10/100/1000BASE-T Ethernet
5
CON (upper), MGT (lower)
3
Ports 17 to 32, 10/100/1000BASE-T Ethernet
6
Ports 45-48, 10GbE

In the cabling table, use the To column that corresponds to the type of SuperCluster that you are cabling.

From
Switch Port No.
Cable
To
Single-Server Models
To
Port
To
Dual-Server Models
To
Port
1
Red
U27 – If present, storage server 11
NET MGT
2
Red
U31 – If present, storage server 9
NET MGT
3
10 ft black
U27 – If present, storage server 11
NET 0
U27 – Compute server, GbE 1
1
4
10 ft black
U31 – If present, storage server 9
NET 0
U27 – Compute server, GbE 1
3
5
10 ft black
U27 – Compute server, GbE 1
0
6
10 ft black
U27 – Compute server, GbE 1
2
7
10 ft black
U27 – Compute server, GbE 0
1
8
10 ft black
U27 – Compute server, GbE 0
3
9
10 ft black
U29– If present, storage server 10
NET 0
U27 – Compute server, GbE 0
0
10
10 ft black
U33 – If present, storage server 8
NET 2
U27 – Compute server, GbE 0
2
11
10 ft red
U29 – If present, storage server 10
NET 0
U27 – Compute server, SP 0
NET MGT
12
10 ft red
U33 – If present, storage server 8
NET MGT
U27 – Compute server, SP 1
NET MGT
13
10 ft black
U8 – Compute server, GbE 1
1
U8 – Compute server, GbE 1
1
14
10 ft black
U8 – Compute server, GbE 1
3
U8 – Compute server, GbE 1
3
15
10 ft black
U8 – Compute server, GbE 1
0
U8 – Compute server, GbE 1
0
16
10 ft black
U8 – Compute server, GbE 1
2
U8 – Compute server, GbE 1
2
17
10 ft black
U8 – Compute server, GbE 0
1
U8 – Compute server, GbE 0
1
18
10 ft black
U8 – Compute server, GbE 0
3
U8 – Compute server, GbE 0
3
19
10 ft black
U8 – Compute server, GbE 0
0
U8 – Compute server, GbE 0
0
20
10 ft black
U8 – Compute server, GbE 0
2
U8 – Compute server, GbE 0
2
21
10 ft red
U8 – Compute server, SP 0
NET MGT
U8 – Compute server, SP 0
NET MGT
22
10 ft red
U8 – Compute server, SP 1
NET MGT
U8 – Compute server, SP 1
NET MGT
23
1m white
PDU B
NET MGT
PDU B
NET MGT
24
1m white
PDU A
NET MGT
PDU A
NET MGT
25
26
27
10 ft blue
U25 – ZFS storage server 1
NET 1
U25 – ZFS storage server 1
NET 1
28
10 ft blue
U26 – ZFS storage server 2
NET 1
U26 – ZFS storage server 2
NET 1
29
10 ft blue
U25 – ZFS storage server 1
NET 0
U25 – ZFS storage server 1
NET 0
30
10 ft blue
U26 – ZFS storage server 2
NET 0
U26 – ZFS storage server 2
NET 0
31
10 ft black
U35 – If present, storage server 7
NET 0
32
10 ft red
U35 – If present, storage server 7
NET MGT
33
10 ft black
U37 – If present, storage server 6
NET 0
U37 – If present, storage server 6
NET 0
34
10 ft red
U37 – If present, storage server 6
NET MGT
U37 – If present, storage server 6
NET MGT
35
10 ft black
U39 – If present, storage server 5
NET 0
U39 – If present, storage server 5
NET 0
36
10 ft red
U39 – If present, storage server 5
NET MGT
U39 – If present, storage server 5
NET MGT
37
10 ft black
U41 – If present, storage server 4
NET 0
U41 – If present, storage server 4
NET 0
38
10 ft red
U41 – If present, storage server 4
NET MGT
U41 – If present, storage server 4
NET MGT
39
10 ft black
U6 – Storage server 3
NET 0
U6 – Storage server 3
NET 0
40
10 ft red
U6 – Storage server 3
NET MGT
U6 – Storage server 3
NET MGT
41
10 ft black
U4 – Storage server 2
NET 0
U4 – Storage server 2
NET 0
42
10 ft red
U4 – Storage server 2
NET MGT
U4 – Storage server 2
NET MGT
43
10 ft black
U2 – Storage server 1
NET 0
U2 – Storage server 1
NET 0
44
10 ft red
U2 – Storage server 1
NET MGT
U2 – Storage server 1
NET MGT
45
10 ft black
U24 – IB switch, leaf 2
NET 0
U24 – IB switch, leaf 2
NET 0
46
10 ft black
U18 – IB switch, leaf 1
NET 0
U18 – IB switch, leaf 1
NET 0
47
10 ft black
U1 – IB switch, spine
NET 0
U1 – IB switch, spine
NET 0
48
unused
unused

Related Information