This example sets the /HOST/diag default_level to min, which configures POST to run according to other parameter values.
-> set /HOST/diag default_level=min Set default_level to min
For possible values for the default_level parameter, type:
-> help /HOST/diag /HOST/diag : Manage Host Power On Self Test Diagnostics Targets: Properties: default_level : Diag level in the default cause (no error or hw change) default_level : Possible values = off, min, max default_level : User role required for set = r default_verbosity : Diag verbosity in the default cause (no error or hw change) default_verbosity : Possible values = none, min, normal, max default_verbosity : User role required for set = r error_level : Diag level when running after an error reset error_level : Possible values = off, min, max error_level : User role required for set = r error_verbosity : Diag verbosity when running after an error reset error_verbosity : Possible values = none, min, normal, max error_verbosity : User role required for set = r hw_change_level : Diag level when running after a hw change hw_change_level : Possible values = off, min, max hw_change_level : User role required for set = r hw_change_verbosity : Diag verbosity when running after a hw change hw_change_verbosity : Possible values = none, min, normal, max hw_change_verbosity : User role required for set = r ->
To set error_level, to max, and to set hw_change_level to max, type:
-> set /HOST/diag error_level=max -> set /HOST/diag hw_change_level=max
Refer to the section on setting the SPARC host keyswitch state in the Oracle ILOM Administratorâs Guide for Configuration and Maintenance Firmware Release 4.0.x for a description of parameters and values.
Example:
-> show /HOST/diag /HOST/diag Targets: Properties: error_reset_level = max error_reset_verbosity = normal hw_change_level = max hw_change_verbosity = normal level = min mode = normal power_on_level = max power_on_verbosity = normal trigger = hw_change error-reset verbosity = normal Commands: cd set show ->