Configure POST

  1. Log in to Oracle ILOM.

    See Log In to Oracle ILOM (Service).

  2. Set /HOST/diag to the value that corresponds to the POST configuration you want to run.

    This example sets the /HOST/diag default_level to min, which configures POST to run according to other parameter values.

    -> set /HOST/diag default_level=min
    Set default_level to min
    

    For possible values for the default_level parameter, type:

    -> help /HOST/diag
    
    /HOST/diag : Manage Host Power On Self Test Diagnostics
    
    Targets:
    
    Properties:
    default_level : Diag level in the default cause (no error or hw change)
    default_level : Possible values = off, min, max
    default_level : User role required for set = r
    
    default_verbosity : Diag verbosity in the default cause (no error or hw change)
    default_verbosity : Possible values = none, min, normal, max
    default_verbosity : User role required for set = r
    
    error_level : Diag level when running after an error reset
    error_level : Possible values = off, min, max
    error_level : User role required for set = r
    
    error_verbosity : Diag verbosity when running after an error reset
    error_verbosity : Possible values = none, min, normal, max
    error_verbosity : User role required for set = r
    
    hw_change_level : Diag level when running after a hw change
    hw_change_level : Possible values = off, min, max
    hw_change_level : User role required for set = r
    
    hw_change_verbosity : Diag verbosity when running after a hw change
    hw_change_verbosity : Possible values = none, min, normal, max
    hw_change_verbosity : User role required for set = r
    
    ->
    

    Note -  When the verbosity value is set to none, the console may not display any POST test status for extended periods of time on certain configurations.
  3. (Optional) Set /HOST/diag to determine the diagnostic level after an error reset and after a hardware change.

    To set error_level, to max, and to set hw_change_level to max, type:

    -> set /HOST/diag error_level=max
    -> set /HOST/diag hw_change_level=max
    

    Refer to the section on setting the SPARC host keyswitch state in the Oracle ILOM Administrator’s Guide for Configuration and Maintenance Firmware Release 4.0.x for a description of parameters and values.

  4. View the current values for settings.

    Example:

    -> show /HOST/diag
    /HOST/diag
       Targets:
     
       Properties:
            error_reset_level = max
            error_reset_verbosity = normal
            hw_change_level = max
            hw_change_verbosity = normal
            level = min
            mode = normal
            power_on_level = max
            power_on_verbosity = normal
            trigger = hw_change error-reset
            verbosity = normal
     
       Commands:
            cd
            set
            show
    -> 

Related Information