Verify a NVMe Switch Card

  1. Use the Oracle ILOM fault management shell to determine if the replacement NVMe switch card is shown as enabled or disabled:
    -> start /SP/faultmgmt/shell
    Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
     
    faultmgmtsp> fmadm faulty
    
    1. If the output from the fmadm faulty command shows no faults, go to Step 2.
    2. If the output from the fmadm faulty command shows the replacement NVMe switch card as disabled, go to Detecting and Managing Faults to clear the PSH-detected fault from the server.
  2. Verify that the front and rear Service Required LEDs are not lit.

    See Front Panel Controls and LEDs and Rear Panel Controls and LEDs.

  3. Consider these options:
    • If the previous steps did not clear the fault, see Diagnostics Process

    • If Step 1 and Step 2 indicate that no faults have been detected, then the processor module has been replaced successfully. No further action is required.