Go to main content
Sun Server X4-4 Service Manual

Exit Print View

Updated: October 2015
 
 

Server Specifications

This section includes physical, electrical and environmental specifications for the system.

Physical Specifications

The following table lists the physical specifications for the Sun Server X4-4.

Parameter
Value
Height
129.9 mm (5.1 inches)
Width
436.5 mm (17.2 inches)
Depth
732 mm (28.8 inches)
752.35 mm (29.6 inches) with PSU ejectors
Weight
40 kg (88 lbs)

Electrical Specifications

The following table lists the electrical specifications for the Sun Server X4-4.


Note -  For up-to-date information on power consumption, refer to: http://www.oracle.com/technetwork/server-storage/sun-x86/overview/index.html
Parameter
Value
Nominal input frequencies
50/60 Hz
Operating input voltage range
100-127 VAC (Two-CPU configuration)
200-240 VAC (Two or Four-CPU configuration)
Rated input current
100-127 VAC 12A (Two-CPU configuration)
200-240 VAC 10A
Maximum power consumption
2000W
Maximum heat output
6824 BTU/hr

Environmental Requirements

The following table lists the environmental requirements for the Sun Server X4-4.

Parameter
Value
Operating temperature (single, non-rack system)
At sea level: 5° C to 35° C (41° F to 95° F)
At altitude: 5° C to 31° C (41° F to 88° F)
Non-operating temperature (single, non-rack system)
-40° C to 68° C (-40° F to 154° F)
Operating humidity (single, non-rack system)
10% to 90% relative humidity, non-condensing
Non-operating humidity (single, non-rack system)
Up to 93% relative humidity, non-condensing
Operating altitude (single, non-rack system)
Up to 3,000 m (9,840 ft), maximum ambient temperature is derated by 1 degree C per 300m above 900 m, except in China where regulations may limit installations to a maximum altitude of 2,000 m
Non-operating altitude (single, non-rack system)
0 m to 12,000 m (0 ft to 40,000 ft)
Acoustic noise
LwAd: 8.9 B (idle and operating, room temp.), 8.9 B (max. ambient); LpAm: 75 dBA (bystander position, max. ambient)