Sun Server X4-4 Service Manual

Exit Print View

Updated: October 2015
 
 

Power On the Server

If you removed power from the server during maintenance, use the following procedure to reapply main power for all server components.

  1. Verify that the power cords are connected to the server and that standby power is on.

    Shortly after power is applied to the server, the SP OK indicator blinks as the service processor boots. The SP OK indicator is illuminated solid green when the service processor has successfully booted. After the service processor has booted, the system OK indicator on the front panel begins flashing slowly, indicating that the host is in standby power mode.

  2. Press and release the recessed Power button on the server front panel.

    When main power is applied to the server, the system OK indicator begins to blink more quickly while the system boots and lights solidly once the operating system boots.

    Each time the server powers on, the power-on self-test (POST) can take several minutes to complete.


    image:An illustration with callouts showing the server front indicator panel.
    Figure Legend
    Description
    1
    System OK indicator
    2
    Power Button
    3
    SP OK indicator