Go to main content
oracle home
Oracle
®
Fabric Interconnect F2-12 Service Manual
Exit Print View
Search Term
Search Scope:
This Document
Entire Library
» ...
Documentation Home
»
Oracle Fabric Interconnect F2-12 Documentation ...
»
Oracle
®
Fabric Interconnect ...
»
Index Numbers and Symbols
Updated: November 2016
Oracle
®
Fabric Interconnect F2-12 Service Manual
Document Information
Using This Documentation
Product Documentation Library
Feedback
Identifying Components
Switch Front Components
Switch Rear Components
Front Panel Components
Rear Panel Components
Detecting and Managing Faults
Troubleshooting the Switch
Begin the Diagnostic Process
Perform Diagnostics at the Switch
Perform Additional Diagnostics at the Switch
Perform Diagnostics Remotely
Perform Oracle ILOM Target Diagnostics
Identifying Components of Faulted Targets
Oracle ILOM /HOST and /SP Target Replaceable Components
Oracle ILOM /System Target Replaceable Components
Oracle ILOM Legacy Target Replaceable Components
Faulted Item Replaceable Components
Diagnostic Tools
Troubleshooting (LEDs)
Inspect the LEDs
Front Panel LEDs
RJ-45 Link LEDs
Component LEDs
Accessing the SP
Access the SP (1GBase-T RJ-45 Port)
Access the SP (SER MGT Port)
Configure and Enable Network Management (SER MGT Port)
Troubleshooting (Oracle ILOM /SP Targets)
Display Oracle ILOM Log Entries
Oracle ILOM Log Entry Filters
Display Network Management Configuration Properties
Display User Session Information
Display the SP Firmware Version
Troubleshooting (Oracle ILOM /System Targets)
Display Problematic Components
Open Problem Faults
Display the General Health of Components and Systems
Oracle ILOM Target Health States
Display Active Power Consumption
Troubleshooting (Oracle ILOM Legacy Targets)
Enable Oracle ILOM Legacy Targets
Display Status for Specific Components
Clear a Fault Manually
Oracle ILOM Legacy Targets for Fault State and FRUID
Oracle ILOM Legacy Targets for Power Consumption
Oracle ILOM Legacy Targets for Voltage
Oracle ILOM Legacy Targets for Temperature
Oracle ILOM Legacy Targets for Fan Speeds
Oracle ILOM Legacy Targets for LED States
Resettable Targets
Preparing for Service
Safety Information
Safety Symbols
ESD Measures
Antistatic Wrist Strap Use
Antistatic Mat
Service Tools
Read the Switch Serial Number (Oracle ILOM)
Locate the Switch
Prevent ESD Damage
Prepare to Power Off the Switch
Power Off the Switch
Servicing Data Cables
Identifying Data Cable Types
PrizmMT Cables
QSFP Cables and Transceivers
RJ-45 Cables
LC Cables
Locate a Faulty Data Cable
Remove a Data Cable
(Optional) Assemble the QSFP and SFP+ Cables
Install a Data Cable
Verify a Data Cable
(Optional) Clean the PrizmMT Receptacle or Connector Ferrule
Servicing Fan Modules
Fan Module LED
Locate a Faulty Fan Module
Remove a Fan Module
Install a Fan Module
Verify a Fan Module
Servicing I/O Modules
Preparing I/O Modules for Service
I/O Module LEDs
Locate a Faulty I/O Module
Disconnect the I/O Module From the Switch Fabric
Remove an I/O Module
Install an I/O Module
Verify an I/O Module
Add the I/O Module to the Switch Fabric
Servicing Filler Panels
Remove a Filler Panel
Install a Filler Panel
Servicing Power Supplies
Power Supply LEDs
Locate a Faulty Power Supply
Remove a Power Supply
Install a Power Supply
Verify a Power Supply
Replacing the Switch
Switch LEDs
Determine if the Switch Is Faulty
Remove the SER MGT Cable
Remove the Switch
Install the Switch
Install the SER MGT Cable
Verify the Switch
Configure the Replacement Switch
Returning the Switch to Operation
Power On the Switch
Verify the Serviced Component
Glossary
Index
Index Numbers and Symbols
Index A
Index C
Index D
Index E
Index F
Index H
Index I
Index L
Index N
Index O
Index P
Index Q
Index R
Index S
Index T
Index U
Index V
Language:
English
Index
Numbers and Symbols
/SP
targets
replaceable components
Oracle ILOM /HOST and /SP Target Replaceable Components
troubleshooting
Troubleshooting (Oracle ILOM /SP Targets)
/SYS
targets
fan speed
Oracle ILOM Legacy Targets for Fan Speeds
fault state
Oracle ILOM Legacy Targets for Fault State and FRUID
FRUID
Oracle ILOM Legacy Targets for Fault State and FRUID
LED states
Oracle ILOM Legacy Targets for LED States
power consumption
Oracle ILOM Legacy Targets for Power Consumption
replaceable components
Oracle ILOM Legacy Target Replaceable Components
temperature
Oracle ILOM Legacy Targets for Temperature
troubleshooting
Troubleshooting (Oracle ILOM Legacy Targets)
voltage
Oracle ILOM Legacy Targets for Voltage
/System/Open_Problems
faults
Open Problem Faults
/System
targets
replaceable components
Oracle ILOM /System Target Replaceable Components
troubleshooting
Troubleshooting (Oracle ILOM /System Targets)
A
accessing the SP
Accessing the SP
1 GBase-T RJ-45 port
Access the SP (1GBase-T RJ-45 Port)
SER MGT port
Access the SP (SER MGT Port)
adding cables
Install a Data Cable
antistatic
mat
Antistatic Mat
wrist strap
Antistatic Wrist Strap Use
assembling cables
(Optional) Assemble the QSFP and SFP+ Cables
C
cables
adding
Install a Data Cable
assembling
(Optional) Assemble the QSFP and SFP+ Cables
identifying
Identifying Data Cable Types
installing
Install a Data Cable
locating faulty
Locate a Faulty Data Cable
PrizmMT
PrizmMT Cables
QSFP
(Optional) Assemble the QSFP and SFP+ Cables
QSFP Cables and Transceivers
removing
Remove a Data Cable
RJ-45
RJ-45 Cables
SER MGT
Remove the SER MGT Cable
servicing
Servicing Data Cables
verifying
Verify a Data Cable
chassis status LEDs
Front Panel LEDs
cleaning
PrizmMT cables
(Optional) Clean the PrizmMT Receptacle or Connector Ferrule
PrizmMT receptacles
(Optional) Clean the PrizmMT Receptacle or Connector Ferrule
clear_fault_action
targets
Resettable Targets
clearing faults manually
Clear a Fault Manually
components
displaying problematic
Display Problematic Components
displaying status
Display Status for Specific Components
front panel
Front Panel Components
identifying faulted
Identifying Components of Faulted Targets
LEDs
Component LEDs
rear panel
Rear Panel Components
resetting
Clear a Fault Manually
configuring the switch
Configure the Replacement Switch
connecting
power cords
Power On the Switch
D
diagnostics
Detecting and Managing Faults
additional
Perform Additional Diagnostics at the Switch
at switch
Perform Diagnostics at the Switch
Oracle ILOM target
Perform Oracle ILOM Target Diagnostics
remote
Perform Diagnostics Remotely
start
Begin the Diagnostic Process
tools
Diagnostic Tools
displaying
active power consumption
Display Active Power Consumption
chassis serial number
Read the Switch Serial Number (Oracle ILOM)
component status
Display Status for Specific Components
firmware version
Display the SP Firmware Version
logs
Display Oracle ILOM Log Entries
network management properties
Display Network Management Configuration Properties
problematic components
Display Problematic Components
systems health
Display the General Health of Components and Systems
user sessions
Display User Session Information
E
enabling
legacy targets
Enable Oracle ILOM Legacy Targets
network management
Configure and Enable Network Management (SER MGT Port)
ESD
antistatic mat
Antistatic Mat
antistatic wrist strap
Antistatic Wrist Strap Use
measures
ESD Measures
preventing
Prevent ESD Damage
F
fan modules
installing
Install a Fan Module
locating faulty
Locate a Faulty Fan Module
removing
Remove a Fan Module
resetting
Verify a Fan Module
servicing
Servicing Fan Modules
status LEDs
Fan Module LED
verifying
Verify a Fan Module
fan speed
/SYS
targets
Oracle ILOM Legacy Targets for Fan Speeds
legacy targets
Oracle ILOM Legacy Targets for Fan Speeds
fault state
/SYS
targets
Oracle ILOM Legacy Targets for Fault State and FRUID
legacy targets
Oracle ILOM Legacy Targets for Fault State and FRUID
faulted item replaceable components
Faulted Item Replaceable Components
faults
/System/Open_Problems
Open Problem Faults
clearing manually
Clear a Fault Manually
faulty
cables
Locate a Faulty Data Cable
fan modules
Locate a Faulty Fan Module
I/O modules
Locate a Faulty I/O Module
power supplies
Locate a Faulty Power Supply
switch
Determine if the Switch Is Faulty
filler panels
installing
Install a Filler Panel
removing
Remove a Filler Panel
servicing
Servicing Filler Panels
firmware version
Display the SP Firmware Version
front panel
components
Front Panel Components
LEDs
Front Panel LEDs
FRUID
/SYS
targets
Oracle ILOM Legacy Targets for Fault State and FRUID
legacy targets
Oracle ILOM Legacy Targets for Fault State and FRUID
H
health states
Oracle ILOM Target Health States
I
I/O modules
adding to switch fabric
Add the I/O Module to the Switch Fabric
disconnecting from switch fabric
Disconnect the I/O Module From the Switch Fabric
installing
Install an I/O Module
locating faulty
Locate a Faulty I/O Module
preparing to remove
Disconnect the I/O Module From the Switch Fabric
removing
Remove an I/O Module
resetting
Verify an I/O Module
servicing
Servicing I/O Modules
status LEDs
I/O Module LEDs
verifying
Verify an I/O Module
identifying
cables
Identifying Data Cable Types
components
Identifying Components
faulted components
Identifying Components of Faulted Targets
inspecting the LEDs
Inspect the LEDs
installing
cable
Install a Data Cable
fan modules
Install a Fan Module
filler panels
Install a Filler Panel
I/O modules
Install an I/O Module
power supplies
Install a Power Supply
PrizmMT cables
Install a Data Cable
RJ-45 cables
Install a Data Cable
SER MGT cable
Install the SER MGT Cable
SFP+ cables
Install a Data Cable
switch
Install the Switch
L
LEDs
chassis status
Switch LEDs
Front Panel LEDs
component
Component LEDs
fan module status
Fan Module LED
front panel
Front Panel LEDs
I/O modules
I/O Module LEDs
inspecting
Inspect the LEDs
Locator
Locate the Switch
Front Panel LEDs
OK
Front Panel LEDs
power supply status
Power Supply LEDs
RJ-45 link
RJ-45 Link LEDs
service action
Front Panel LEDs
SP
Front Panel LEDs
state
/SYS
targets
Oracle ILOM Legacy Targets for LED States
legacy targets
Oracle ILOM Legacy Targets for LED States
troubleshooting
Troubleshooting (LEDs)
legacy targets
enabling
Enable Oracle ILOM Legacy Targets
fan speed
Oracle ILOM Legacy Targets for Fan Speeds
fault state
Oracle ILOM Legacy Targets for Fault State and FRUID
FRUID
Oracle ILOM Legacy Targets for Fault State and FRUID
LED states
Oracle ILOM Legacy Targets for LED States
power consumption
Oracle ILOM Legacy Targets for Power Consumption
replaceable components
Oracle ILOM Legacy Target Replaceable Components
temperature
Oracle ILOM Legacy Targets for Temperature
troubleshooting
Troubleshooting (Oracle ILOM Legacy Targets)
voltage
Oracle ILOM Legacy Targets for Voltage
locating faulty
cables
Locate a Faulty Data Cable
fan modules
Locate a Faulty Fan Module
I/O modules
Locate a Faulty I/O Module
power supplies
Locate a Faulty Power Supply
switch
Determine if the Switch Is Faulty
locating the switch
Locate the Switch
Locator LED
Front Panel LEDs
log
displaying
Display Oracle ILOM Log Entries
filters
Oracle ILOM Log Entry Filters
N
network management
displaying properties
Display Network Management Configuration Properties
enabling
Configure and Enable Network Management (SER MGT Port)
O
OK LED
Front Panel LEDs
P
power consumption
/SYS
targets
Oracle ILOM Legacy Targets for Power Consumption
displaying
Display Active Power Consumption
legacy targets
Oracle ILOM Legacy Targets for Power Consumption
power cords
connecting
Power On the Switch
disconnecting
Power Off the Switch
power supplies
installing
Install a Power Supply
locating faulty
Locate a Faulty Power Supply
powering off
Power Off the Switch
powering on
Power On the Switch
removing
Remove a Power Supply
resetting
Verify a Power Supply
servicing
Servicing Power Supplies
status LEDs
Power Supply LEDs
verifying
Verify a Power Supply
powering off
power supplies
Power Off the Switch
switch
Power Off the Switch
powering on
power supplies
Power On the Switch
switch
Power On the Switch
preparing
for service
Preparing for Service
to power off the switch
Prepare to Power Off the Switch
PrizmMT cables
PrizmMT Cables
adding
Install a Data Cable
cleaning
(Optional) Clean the PrizmMT Receptacle or Connector Ferrule
installing
Install a Data Cable
removing
Remove a Data Cable
verifying
Verify a Data Cable
Q
QSFP cables
QSFP Cables and Transceivers
assembling
(Optional) Assemble the QSFP and SFP+ Cables
R
rear panel components
Rear Panel Components
rear panel, LEDs
RJ-45 Link LEDs
Front Panel LEDs
removing
cable
Remove a Data Cable
fan modules
Remove a Fan Module
filler panels
Remove a Filler Panel
I/O modules
Remove an I/O Module
power cords
Power Off the Switch
power supplies
Remove a Power Supply
PrizmMT cables
Remove a Data Cable
RJ-45 cables
Remove a Data Cable
SER MGT cable
Remove the SER MGT Cable
SFP+ cables
Remove a Data Cable
switch
Remove the Switch
replaceable components
/HOST
targets
Oracle ILOM /HOST and /SP Target Replaceable Components
/SP
targets
Oracle ILOM /HOST and /SP Target Replaceable Components
/SYS
targets
Oracle ILOM Legacy Target Replaceable Components
/System
targets
Oracle ILOM /System Target Replaceable Components
faulted item
Faulted Item Replaceable Components
legacy targets
Oracle ILOM Legacy Target Replaceable Components
replacing the switch
Replacing the Switch
resettable targets
Resettable Targets
resetting
components
Clear a Fault Manually
fan modules
Verify a Fan Module
I/O modules
Verify an I/O Module
power supplies
Verify a Power Supply
RJ-45 cables
RJ-45 Cables
adding
Install a Data Cable
installing
Install a Data Cable
link LEDs
RJ-45 Link LEDs
removing
Remove a Data Cable
verifying
Verify a Data Cable
S
safety
information
Safety Information
symbols
Safety Symbols
SER MGT cable
installing
Install the SER MGT Cable
removing
Remove the SER MGT Cable
service action LED
Front Panel LEDs
service tools
Service Tools
servicing
cables
Servicing Data Cables
fan modules
Servicing Fan Modules
filler panels
Servicing Filler Panels
I/O modules
Servicing I/O Modules
power supplies
Servicing Power Supplies
SFP+ cables
adding
Install a Data Cable
installing
Install a Data Cable
removing
Remove a Data Cable
verifying
Verify a Data Cable
SP
accessing
Accessing the SP
1 GBase-T RJ-45 port
Access the SP (1GBase-T RJ-45 Port)
SER MGT port
Access the SP (SER MGT Port)
LED
Front Panel LEDs
start diagnostics
Begin the Diagnostic Process
switch
additional diagnostics
Perform Additional Diagnostics at the Switch
configuring
Configure the Replacement Switch
determining faulty
Determine if the Switch Is Faulty
diagnostics at
Perform Diagnostics at the Switch
front components
Switch Front Components
installing
Install the Switch
locating
Locate the Switch
Oracle ILOM target diagnostics
Perform Oracle ILOM Target Diagnostics
powering off
Power Off the Switch
powering on
Power On the Switch
preparing to power off
Prepare to Power Off the Switch
rear components
Switch Rear Components
remote diagnostics
Perform Diagnostics Remotely
removing
Remove the Switch
replacing
Replacing the Switch
returning to operation
Returning the Switch to Operation
status LEDs
Switch LEDs
troubleshooting
Troubleshooting the Switch
verifying
Verify the Switch
switch fabric
adding I/O modules
Add the I/O Module to the Switch Fabric
disconnecting I/O modules
Disconnect the I/O Module From the Switch Fabric
symbols used in the documentation
Safety Symbols
systems health
Display the General Health of Components and Systems
T
targets that are resettable
Resettable Targets
temperature
/SYS
targets
Oracle ILOM Legacy Targets for Temperature
legacy targets
Oracle ILOM Legacy Targets for Temperature
tools
diagnostics
Diagnostic Tools
service
Service Tools
troubleshooting
Detecting and Managing Faults
/SP
targets
Troubleshooting (Oracle ILOM /SP Targets)
/SYS
targets
Troubleshooting (Oracle ILOM Legacy Targets)
/System
targets
Troubleshooting (Oracle ILOM /System Targets)
LEDs
Troubleshooting (LEDs)
legacy targets
Troubleshooting (Oracle ILOM Legacy Targets)
switch
Troubleshooting the Switch
U
user sessions
Display User Session Information
V
verifying
cables
Verify a Data Cable
fan modules
Verify a Fan Module
I/O modules
Verify an I/O Module
power supplies
Verify a Power Supply
PrizmMT cables
Verify a Data Cable
RJ-45 cables
Verify a Data Cable
SFP+ cables
Verify a Data Cable
switch
Verify the Switch
voltage
/SYS
targets
Oracle ILOM Legacy Targets for Voltage
legacy targets
Oracle ILOM Legacy Targets for Voltage
Previous