Go to main content
Oracle® Fabric Interconnect F2-12 Service Manual

Exit Print View

Updated: November 2016
 
 

Access the SP (SER MGT Port)

  1. Access a terminal server or serial interface connected to the SER MGT port.
  2. Ensure that the serial device is configured with correct parameters.
    • Baud – 9600

    • Data bits – 8

    • Parity – N

    • Stop bits – 1

    • Flow control – None

  3. Press the Return or Enter key on the serial device several times to synchronize the connection.
    Hostname login:
    ->

    where Hostname is the host name of the SP.

  4. Log in to the Oracle ILOM interface with the user name that manages the SP, and its password.

    The default user name is root, and the password is changeme.

    The CLI prompt is displayed, and you can now manage the SP.

  5. If you performed this task as part of a troubleshooting operation, return to the troubleshooting process.

    See Perform Diagnostics Remotely.

Related Information