Go to main content
Oracle® Fabric Interconnect F2-12 Service Manual

Exit Print View

Updated: November 2016
 
 

Perform Diagnostics at the Switch

  1. Are you starting a new troubleshooting session with this task?
  2. Are any power supply LEDs on?
  3. Check the power cords and supplied power, and correct as necessary.

    Refer to the Oracle Fabric Interconnect F2-12 Installation Guide, then return to Step 2.

  4. Is a power supply amber Attention LED on?
  5. Release the tab and unseat the faulted power supply, wait a minute, then reseat the power supply and secure the tab.
  6. Does the power supply Attention LED persist?
  7. Is the green SP LED off?
  8. Is a 1GBASE-T port or SFP+ port used for the network management interface?
  9. Is the port's Link LED on?
  10. Does the Link LED flash on occasion?
  11. Are you sure you know that the cabling is wired correctly with good cables and firm connections?
  12. Inspect and replace cabling as necessary.

    Then return to Step 9.

  13. Are you sure you know that the communication hardware (terminals, routers, and switches) are fully functional?
  14. Inspect and replace communication hardware as necessary.

    Then return to Step 9.

  15. Use new cabling and connect to a different 1GBASE-T port or SFP+ port.

    Go to Step 9. If you arrive back at this step a second time, go to Step 16.

  16. Remove the faulted component and install a new component.

    See Faulted Item Replaceable Components for links to service tasks.

  17. Perform further diagnostics.

    See Perform Additional Diagnostics at the Switch.

Related Information