Go to main content
Oracle® Fabric Interconnect F2-12 Service Manual

Exit Print View

Updated: November 2016
 
 

Oracle ILOM Legacy Targets for Fault State and FRUID

This table lists components that might be in a fault state, or have FRUID information. See Oracle ILOM Legacy Target Replaceable Components or Faulted Item Replaceable Components for a link to the service task for that component.

Faulted Sensor
Oracle ILOM Target
Component to Be Replaced
Exhaust air temperature
/SYS/MB/T_OUT
Switch
Fan module x fan y speed
/SYS/FMx/FANy/TACH
Fan module x
Fan module x presence
/SYS/FMx/PRSNT
Fan module x
HCA temperature
/SYS/MB/T_HCA
Switch
IB switch chip temperature
/SYS/MB/T_IBSWITCH
Switch
Intake air temperature
/SYS/MB/T_AMB
Switch
Main board fault and FRUID
/SYS/MB
Switch
Power supply x fault and FRUID
/SYS/PSx
Power supply x
Power supply x input current
/SYS/PSx/I_IN
Power supply x
Power supply x input power consumed
/SYS/PSx/INPUT_POWER
Power supply x
Power supply x input voltage
/SYS/PSx/V_IN
Power supply x
Power supply x OK state
/SYS/PSx/PWROK
Power supply x
Power supply x output current
/SYS/PSx/I_OUT
Power supply x
Power supply x output power delivered
/SYS/PSx/OUTPUT_POWER
Power supply x
Power supply x output voltage
/SYS/PSx/V_OUT
Power supply x
Power supply x presence
/SYS/PSx/PRSNT
Power supply x
RTC backup battery
/SYS/MB/V_VBAT
Battery
SP fault and FRUID
/SYS/SP
Switch
Standby voltage
/SYS/PS_3V3
Power supplies
I/O module
/SYS/MODULES/MODULEx
I/O modules
I/O module boot state
/SYS/MODULES/MODULEx/BOOTED
I/O modules
I/O module fault
/SYS/MODULES/MODULEx/FAULT
I/O modules
I/O module temperature
/SYS/MODULES/MODULEx/T_CRITICAL
I/O modules
Voltage received by I/O modules
  • /SYS/MODULES/MODULEx/0V85_OK

  • /SYS/MODULES/MODULEx/1V0_OK

  • /SYS/MODULES/MODULEx/1V2_OK

  • /SYS/MODULES/MODULEx/1V8_OK

  • /SYS/MODULES/MODULEx/2V5_OK

  • /SYS/MODULES/MODULEx/3V3_OK

I/O modules

Related Information