Oracle ILOM Legacy Targets for Fault State and FRUID
This table lists components that might be in a fault state, or have FRUID
information. See Oracle ILOM Legacy Target Replaceable Components or Faulted Item Replaceable Components for a link to the
service task for that component.
|
|
|
Exhaust air temperature
|
/SYS/MB/T_OUT
|
Switch
|
Fan module x fan
y speed
|
/SYS/FMx/FANy/TACH
|
Fan module x
|
Fan module x presence
|
/SYS/FMx/PRSNT
|
Fan module x
|
HCA temperature
|
/SYS/MB/T_HCA
|
Switch
|
IB switch chip temperature
|
/SYS/MB/T_IBSWITCH
|
Switch
|
Intake air temperature
|
/SYS/MB/T_AMB
|
Switch
|
Main board fault and FRUID
|
/SYS/MB
|
Switch
|
Power supply x fault and
FRUID
|
/SYS/PSx
|
Power supply x
|
Power supply x input current
|
/SYS/PSx/I_IN
|
Power supply x
|
Power supply x input power
consumed
|
/SYS/PSx/INPUT_POWER
|
Power supply x
|
Power supply x input voltage
|
/SYS/PSx/V_IN
|
Power supply x
|
Power supply x OK state
|
/SYS/PSx/PWROK
|
Power supply x
|
Power supply x output
current
|
/SYS/PSx/I_OUT
|
Power supply x
|
Power supply x output power
delivered
|
/SYS/PSx/OUTPUT_POWER
|
Power supply x
|
Power supply x output
voltage
|
/SYS/PSx/V_OUT
|
Power supply x
|
Power supply x presence
|
/SYS/PSx/PRSNT
|
Power supply x
|
RTC backup battery
|
/SYS/MB/V_VBAT
|
Battery
|
SP fault and FRUID
|
/SYS/SP
|
Switch
|
Standby voltage
|
/SYS/PS_3V3
|
Power supplies
|
I/O module
|
/SYS/MODULES/MODULEx
|
I/O modules
|
I/O module boot state
|
/SYS/MODULES/MODULEx/BOOTED
|
I/O modules
|
I/O module fault
|
/SYS/MODULES/MODULEx/FAULT
|
I/O modules
|
I/O module temperature
|
/SYS/MODULES/MODULEx/T_CRITICAL
|
I/O modules
|
Voltage received by I/O modules
|
-
/SYS/MODULES/MODULEx/0V85_OK
-
/SYS/MODULES/MODULEx/1V0_OK
-
/SYS/MODULES/MODULEx/1V2_OK
-
/SYS/MODULES/MODULEx/1V8_OK
-
/SYS/MODULES/MODULEx/2V5_OK
-
/SYS/MODULES/MODULEx/3V3_OK
|
I/O modules
|
|