Go to main content
Oracle® Fabric Interconnect F2-12 Service Manual

Exit Print View

Updated: November 2016
 
 

Oracle ILOM Log Entry Filters

When you display the Oracle ILOM log, you can filter the output to specific classes and types of entries using combinations of the Class and Type parameters. See Display Oracle ILOM Log Entries. This table describes the combinations and entries that are displayed.

Parameters
Entries Displayed
Class==Audit Type==Log
Commands that result in a configuration change. Description includes user, command, command parameters, and success or failure.
Class==IPMI Type==Log
Any event that is placed in the IPMI system event log is also put into the management log.
Class==Chassis Type==State
Changes to the component inventory and general switch state.
Class==Chassis Type==Action
Shutdown events for switch chassis, hot-insert, and hot-removal of components.
Class==Fault Type==Fault
Fault management faults. Description gives the time the fault was detected and the suspect component.
Class==Fault Type==Repair
Fault management repairs. Description gives the component name.

The output can be further filtered with the Severity parameter, which has one of five values:

  • Debug

  • Down

  • Critical

  • Major

  • Minor

For example, to display only log entries indicating a minor change to the switch inventory, type:

-> show /SP/logs/event/list Class==Chassis Type==State Severity==Minor