ZS3-2 PCIe I/O Cards
ZS3-2 PCIe I/O Options - The following table describes
the supported PCIe configuration options for the ZS3-2 controller. Slots 1 and 2 are reserved
for internal and external HBAs, as shown in the following table. When adding PCIe cards,
populate from higher order slots (6) first toward lower order slots.
Note -
Any empty PCIe slots must have a filler panel installed.
Table 31 ZS3-2 Controller PCIe Configuration Options
|
|
|
|
|
1
|
7047852
|
8-port SAS-2 internal HBA
|
1
|
Base configuration
|
2
|
7067091
|
4-port (4x4) SAS external HBA
|
2
|
Base configuration
|
3
|
7067091
|
4-port (4x4) SAS external HBA
|
2
|
Second 4x4-port SAS external HBA
|
3
|
7070195
|
4-port 1Gb Ethernet Copper UTP NIC
|
4
|
Optional recommended front-end
|
3
|
371-4325-02
|
2-port 8Gb FC HBA
|
4
|
Optional FC target or initiator (backup)
|
3
|
7023303
|
2-port 16Gb FC HBA
|
4
|
Optional FC target or initiator (backup)
|
3
|
375-3696-01
|
2-port InfiniBand CX2 HCA
|
4
|
Optional recommended front-end
|
3
|
7051223
|
2-port 10Gb Ethernet Optical NIC
|
4
|
Optional recommended front-end
|
3
|
7070006
|
2-port 10Gb Ethernet Copper Base-T NIC
|
4
|
Optional recommended front-end
|
4-6
|
7070195
|
4-port 1Gb Ethernet Copper UTP NIC
|
4
|
Optional recommended front-end
|
4-6
|
371-4325-02
|
2-port 8Gb FC HBA
|
4
|
Optional FC target or initiator (backup)
|
4-6
|
7023303
|
2-port 16Gb FC HBA
|
4
|
Optional FC target or initiator (backup)
|
4-6
|
375-3696-01
|
2-port InfiniBand CX2 HCA
|
4
|
Optional recommended front-end
|
4-6
|
7051223
|
2-port 10Gb Ethernet Optical NIC
|
4
|
Optional recommended front-end
|
4-6
|
7070006
|
2-port 10Gb Ethernet Copper Base-T NIC
|
4
|
Optional recommended front-end
|
|
ZS3-2 NIC/HBA Options - The following table describes
the NIC/HBA options for the ZS3-2 controller.
Table 32 ZS3-2 Controller NIC/HBA Options
|
|
SG-SAS6-INT-Z
|
8-port 6Gb/s SAS-2 internal HBA
|
SG-XPCIE2FC-QF8-Z
|
2-port 8Gb FC HBA
|
7103791
7110372
|
4-port (4x4) SAS-3 12 Gb/s external HBA
4-port (4x4) SAS-2 6Gb/s external HBA
|
7101674
|
2-port 16Gb FC HBA
|
X1109A-Z
|
2-port 10GbE SFP+ NIC
|
X4242A
|
2-port InfiniBand CX2 HCA
|
7100477
|
4-port 1Gb Ethernet Copper UTP NIC
|
7100488
|
2-port 10Gb Ethernet Copper Base-T NIC
|
X2129A
|
XCVR 850NM, 1/10GPS, SFP, short reach
|
X5562A-Z
|
10GbE/1GbE SFP+ Transceiver, long reach
|
|
ZS3-2 PCIe Riser Configuration - The three risers are
labeled Riser 1, Riser 2, and Riser 3. Though similar, the risers are not interchangeable.
Riser 1 installs at the left rear of the chassis, Riser 2 at the center rear, and Riser 3 at
the right rear of the chassis. Each riser can accommodate two PCIe cards:
-
Riser 1 contains slots 1 and 4
-
Riser 2 contains slots 2 and 5
-
Riser 3 contains slots 3 and 6