Replacing a ZS5-4 HDD

HDDs are hot-swappable and can be removed and installed while the storage controller is running without affecting other hardware capabilities. Use the following procedure to replace a ZS5-4 HDD. For information on disk compatibility, see the Oracle Systems Handbook.


Note -  If you have more than one failed drive, replace only one drive at a time. Removing more than one drive in quick succession will cause a hardware/pool fault. Also, do not perform a pool configuration operation while a disk firmware upgrade is occurring. To check if an upgrade is in progress, navigate to Maintenance > System in the BUI, or maintenance system updates in the CLI.
  1. Identify the faulted HDD.
    • If you are not physically at the system, go to the Maintenance > Hardware section of the BUI, click the right-arrow icon for the controller, and note the ID of the faulted drive, which has an amber icon. To highlight the location of the drive in the controller picture, click on the drive ID. To view details about the faulted drive, click its information icon and then click Active Problems.

    • If you are physically at the system, the amber Service Action Required indicator on the HDD should be lit. Additionally, you can click the locator icon image:locate icon in the BUI to flash the locator indicator on the faulted drive.

  2. Verify that the Ready to Remove indicator is lit on the faulted drive.
  3. On the drive you want to remove, push the drive release button (1) to open the latch.
  4. Grasp the latch (2) and pull the drive out of the drive slot (3).
    image:A multi-step illustration showing how to remove a storage drive                                 from the server.
  5. After at least 30 seconds, go to the Hardware > Maintenance screen, and click the right-arrow icon image:apply icon on the system controller to verify that the software has detected that the drive is not present.
  6. On the replacement drive, open the release lever and Slide the drive into the same slot (1) until it is fully seated. Close the latch (2) to lock the drive in place.
    image:A multi-step illustration showing how to install a storage                                 drive in the server.

    The oracle ZFS Storage Appliance software automatically detects and configures the new drive.

  7. Go to the Maintenance > Hardware screen of the BUI. Click the right-arrow icon for the controller, and verify that the status icon image:status icon is green for the newly installed drive. To view details about the new drive, click its information icon.
  8. If a fault does not self-clear, see Repairing Active Problems.