Go to main content

Oracle® ZFS Storage Appliance Customer Service Manual

Exit Print View

Updated: September 2018
 
 

7320 Configuration Options

7320 Chassis Overview - The Sun ZFS Storage 7320 consists of either a standalone storage controller or two storage controllers in a high availability cluster configuration. Both the standalone and clustered configuration supports one to six disk shelves.

The 7320 controller base configuration includes two CPUs, built-in 4 x 1Gb/s front-end GigE ports, redundant power supplies, NIC options for expanded front-end support, tape backup, InfiniBand, and dual port SAS HBA for storage expansion.

The CPUs are Intel Xeon 5600 series, 2.40GHz, 80W, with 4 core processors. The standard memory configuration is 96GB, 6 x 8GB DDR3-1333 low voltage (LV) DIMMs per CPU. Memory can be upgraded to 144GB using 9 x 8GB DDR3-1333 LV DIMMs per CPU (for a total of 18 x 8GB for two CPUs). Earlier versions of the 7320 controller included 24GB (base), 48GB, or 72GB memory options. The clustered configuration simply uses two servers and a cluster card in each server for a heartbeat connection between the servers.

All user-accessible storage is provided by one to six disk shelves that are external to the server(s). RAID functions are managed by software. Solid state SAS-1 drives (7320 SAS-2) are used for a high-performance write cache (known as LogZilla) or ZFS intent log (ZIL) devices, and are used in place of up to four of the 24 drives in a disk shelf. The remaining 20 drives are available for storage.

Refer to the product site at https://www.oracle.com/storage/nas/index.html for the most recent component specification.

The 7320 is a SAS-2 (Serial Attached SCSI 2.0) device that consists of an HBA, disk shelf, and disks. The SAS-2 storage fabric supports a greater number of targets, greater bandwidth, higher reliability, and bigger scale than the SAS-1 fabric. For information about supported disks and capacities, refer to the Oracle Systems Handbook.

Standalone Controller Configuration - The standalone controller base configuration is 96GB RAM, 2x2.4GHz Quad-Core processors, one external SAS HBA, and four 10/100/1000 Ethernet ports.

The following table describes base configurations for the 7320.

Table 38  7320 Controller Base Configurations
Mktg Part Number
Description
Mfg Part Number
TA7320-24A
S7320, 2xCPU, 24GB, Single
597-1060-01
7104054
S7320, 2xCPU, 96GB, Single
7045900
TA7320-24A-HA
S7320, 2xCPU, 24GB, Cluster
597-1061-01
7104055
S7320, 2xCPU, 96GB, Cluster
7045903

Following are the PCIe configuration options for a standalone controller. All PCIe cards are low profile and must be fitted with low-profile mounting brackets.

Table 39  7320 Standalone Controller PCIe Configuration Options
Slot
Type
Part Number
Vendor Part
Description
Note
0
PCIe
375-3617-01
Intel Niantic
DP Optical 10GE NIC
Optional Recommended Front-end
0
PCIe
375-3696-01
Mellanox
InfiniBand HCA
Optional Recommended Front-end
0
PCIe
375-3606-03
MHJH29-XTC
InfiniBand HCA
Optional Recommended Front-end
0
PCIe
375-3481-01
Intel EXPI9404PT
QP Copper NIC
Optional Recommended Front-end
0
PCIe
371-4325-01
QLogic
8Gb DP FC HBA
Optional FC Target or Initiator (Backup)
1
PCIe
375-3617-01
Intel Niantic
DP Optical 10GE NIC
Optional Recommended Front-end
1
PCIe
375-3696-01
Mellanox
InfiniBand HCA
Optional Recommended Front-end
1
PCIe
375-3606-03
MHJH29-XTC
InfiniBand HCA
Optional Recommended Front-end
1
PCIe
375-3481-01
Intel EXPI9404PT
QP Copper NIC
Optional Recommended Front-end
1
PCIe
371-4325-01
QLogic
8Gb DP FC HBA
Optional FC Target or Initiator (Backup)
2
PCIe
375-3609-03
Sun Thebe
External SAS HBA
Base Configuration

7320 Cluster Configurations - The 7320 cluster base configuration is 96GB RAM, 2x2.4GHz Quad-Core processors, one external SAS HBA, and four 10/100/1000 Ethernet ports, and a Cluster card. The Sun Storage 7420C Cluster Upgrade Kit (XOPT 594-4680-01) contains two cluster cards with cables for converting two 7320 or two 7420 controllers to a cluster.

The following options are available for clustered storage controllers.


Note -  When you cluster a 7320, you must identically configure the cards in both of the clustered storage controllers, and you must identically configure all optional NIC/HBA cards used in the clustered storage controllers in both chassis.
Table 40  7320 Clustered Controllers Configurations
Slot
Type
Part Number
Vendor Part
Description
Note
0
PCIe
375-3617-01
Intel Niantic
DP Optical 10GE NIC
Optional Recommended Front-end
0
PCIe
375-3696-01
Mellanox
InfiniBand HCA
Optional Recommended Front-end
0
PCIe
375-3606-03
MHJH29-XTC
InfiniBand HCA
Optional Recommended Front-end
0
PCIe
375-3481-01
Intel EXPI9404PT
QP Copper NIC
Optional Recommended Front-end
0
PCIe
371-4325-01
QLogic
8Gb DP FC HBA
Optional FC Target or Initiator (Backup)
1
PCIe
542-0298-01
Sun
Fishworks Cluster Card 2
Cluster Base Configuration
2
PCIe
375-3609-03
Sun Thebe
External SAS HBA
Cluster Base Configuration