The ZS3-2 chassis has the following field replaceable units ( FRUs). FRUs are not customer-serviceable and must be replaced by trained Oracle service technicians.
PCIe Risers - There are three risers per system, each attached to the rear of the motherboard. Each riser supports two PCIe cards (which are customer replaceable units (CRUs).
Motherboard - The motherboard includes CPU modules, slots for 16 DIMMs, memory control subsystems, and the service processor (SP) subsystem. The SP subsystem controls the host power and monitors host system events (power and environmental). The SP controller draws power from the host 3.3V standby supply rail, which is available whenever the system is receiving AC input power, even when the system is turned off.
Power Distribution Board - The power distribution board distributes main 12V power from the power supplies to the rest of the controller. It is directly connected to the connector break out board and to the motherboard through a bus bar and ribbon cable. It also supports a top cover interlock kill switch. The power supplies connect directly to the power distribution board.
Storage Drive Backplane - The storage drive backplane includes the connectors for the storage drives, as well as the interconnect for the I/O board, power and locator buttons, and system/component status LEDs. The system has an 8-disk backplane. Each drive has an LED indicator for Power/Activity, Fault, and Locate.
ZS3-2 Motherboard, Memory, and PCIe Cards - The ZS3-2 controller motherboard, memory, and PCIe components are described in the following figure and legend.
Figure 42 ZS3-2 Controller Motherboard, Memory, and PCIe Components
|
ZS3-2 CPU and Memory - The ZS3-2 controller motherboard has 16 slots in two groups that hold industry-standard DDR3 low voltage (LV) DIMMS.
Figure 43 ZS3-2 Controller CPU and Memory Components
|
The ZS3-2 controller replaceable memory components and part numbers are listed below.
|
ZS3-2 Storage, Power, and Fan Components - The ZS3-2 controller's internal storage, power, and cooling components are described in the following figure and legend. A component identified as a field replaceable unit ( FRU) must be replaced by trained Oracle service technicians.
Figure 44 ZS3-2 Controller Storage, Power, and Fan Components
|
ZS3-2 Internal Cables - The ZS3-2 controller contains the following field-replaceable unit ( FRU) internal cables. FRUs are not customer-serviceable, and must be replaced by trained Oracle service technicians.
Figure 45 ZS3-2 Controller Internal Cables
|