Go to main content

Oracle® ILOM Administrator's Guide for Configuration and Maintenance Firmware Release 3.2.x

Exit Print View

Updated: November 2019
 
 

System Management Power Supply Policies Configurable From CMM

System administrators can optionally set system management policies from the CMM to manage chassis power supply demand, power supply fan speeds, storage blade SAS-2 capability, and chassis power management.

For property descriptions of the system management policies that are configurable from the CMM, see the following table:

Table 85  Configurable CMM Power Supply Policies
User Interface Configurable Target and User Role:
  • CLI: /CMM/policy - or - /CH/BLn/SP/policy

  • Web: System Management > Policy > Policy Configuration

  • User Role: admin (a) (required for all property modifications)

System Management Policy
Default
Description
Light Load Efficiency Mode
(LIGHT_LOAD_EFFICIENCY_MODE=)
Disabled
Disabled |Enabled
Enable this policy to: 1) monitor the chassis system power usage; and 2) automatically shut down the power supply unit sides to achieve higher efficiency.
CLI Syntax for Light Load Efficiency Mode:
set /CMM/policy LIGHT_LOAD_EFFICIENCY_MODE=enabled|disabled
Monitor Power Supply 0 Side 0 for power
(MONITOR_PS0_SIDE0=)
Enabled
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 0 Side 0 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply 0 Side 0:
set /CMM/policy MONITOR_PS0_SIDE0=enabled|disabled
Monitor Power Supply 0 Side 1 for power
(MONITOR_PS0_SIDE1=)
Enabled
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 0 Side 1 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply 0 Side 1:
set /CMM/policy MONITOR_PS0_SIDE1=enabled|disabled
Monitor Power Supply 1 Side 0 for power
(MONITOR_PS1_SIDE0=)
Enabled
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 1 Side 0 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply 1 Side 0:
set /CMM/policy MONITOR_PS1_SIDE0=enabled|disabled
Monitor Power Supply 1 Side 1 for power
(MONITOR_PS1_SIDE1=)
Enabled
Disabled |Enabled
Enable this policy to enable monitoring of Power Supply 1 Side 1 under Light Load Efficiency Mode.
CLI Syntax for Monitor Power Supply 1 Side 1:
set /CMM/policy MONITOR_PS1_SIDE1=enabled|disabled
Cooling Door Installed
(COOLING_DOOR_INSTALLED=)
Disabled
Disabled |Enabled
Enable this policy to support a cooling door installed on a Sun Blade 6048 chassis.
CLI Syntax for Cooling Door Installed:
set /CMM/policy COOLING_DOOR_INSTALLED=enabled|disabled
Force Power Supply Fans to High Speed
(PS_FANS_HIGH=)
Disabled
Disabled |Enabled
Enable this policy to force the power supply fans to 100% capacity.
CLI Syntax for Force Power Supply Fans to High Speed:
set /CMM/policy PS_FANS_HIGH=enabled|disabled
Force Power Supply Fans to Low Speed
(PS_FANS_LOW=)
Disabled
Disabled |Enabled
Enable this policy to force the power supply fans to 80% capacity.
CLI Syntax for Force Power Supply Fans to Low Speed:
set /CMM/policy PS_FANS_LOW=enabled|disabled
Force Server Blade to be SAS2 Capable at 3Gbps.
(FORCE_SAS2_3GBPS=)
Disabled
Disabled |Enabled
Enable this policy to force the NEM(s) to run the SAS link at a slower rate, for those rare cases when this action is necessary.
CLI Syntax for Force Server Blade to be SAS2 Capable at 3Gbps:
set /CH/BLn/SP/policy FORCE_SAS2_3GBPS=enabled|disabled
Manage chassis power.

Caution  - Disabling may lead to chassis shutdown.

(POWER_MANAGEMENT=)
Enabled
Disabled |Enabled
Enable this policy to determine whether there is enough power in the chassis to power on a new server module installed in the chassis.
CLI Syntax for Manage Chassis Power:

Caution  - Disabling may lead to chassis shutdown.

set /CMM/policy POWER_MANAGEMENT=enabled|disabled

Related Information