Precautions (Storage Array)

Observe the following cautions when installing the storage array into a rack using the supplied rail kit. Note that if your rail kit shipped with installation instructions, use those instructions instead.

  • Always load equipment into a rack from the bottom up so that it will not become top-heavy and tip over. Deploy the anti-tip bar to prevent the rack from tipping during equipment installation.

  • Ensure that the temperature in the rack does not exceed the controller's maximum ambient rated temperatures. Consider the total airflow requirements of all equipment installed in the rack to ensure that the equipment is operated within its specified temperature range.

  • Do not remove a component if you do not have an immediate replacement. The storage array must not be operated without all components in place.

  • Do not lift the storage array by the handles on the power supply with fan modules; they are not designed to take the weight.