1.
|
Mount the compute nodes and storage array in a rack, if
necessary.
|
|
|
2.
|
Connect to the NET MGT port.
|
You must connect to the NET MGT port as part of the software
configuration process. Connect a Category 5 (or better) RJ-45 cable
from the NET MGT ports on both compute nodes to your network switch
or hub. See Connect the Management Network.
|
|
3.
|
Connect the 10GbE client access network.
|
Connect from both compute nodes to the 10GbE client access network
through either:
|
|
4.
|
Connect the 10GbE private network.
|
The 10GbE private network transfers data between the two compute
nodes. It is also used for the RAC interconnect when Oracle RAC is
installed on the MiniCluster.
Connect the NET 0 and NET 1 ports from one compute node to the
other compute node.
|
|
5.
|
Connect the storage arrays to the compute nodes.
|
Connect the storage arrays to the compute nodes using:
|
|
6.
|
Connect to the SER MGT port.
|
Connect to the SER MGT port to assign a static IP address to the
NET MGT port.
Connect a Category 5 (or better) RJ-45 cable from the SER MGT port
on compute node 1 to a terminal device.
|
|
7.
|
Connect the power cords and power on the storage array and two
compute nodes.
|
-
For the storage array, plug the power cords to the two
power supplies, and push the on/off switches on both power
supplies to the on (I) position.
-
For the two compute nodes, plug the power cords to the two
power supplies. Power on the compute nodes by either
pressing the System Power buttons on both compute nodes or
entering start /SYSTEM at the ILOM