Go to main content

SPARC M8 and SPARC M7 Servers Installation Guide

Exit Print View

Updated: September 2017
 
 

Connect Terminals or Emulators to the SP SER MGT Ports

Prior to powering on the server for the first time, make serial connections to the two SPs. After making these serial connections, you will be able to view the system status and error messages when you supply power to the server.


Note -  If you supply power to the server without first connecting terminals to the SER MGT 0 ports, you will not see the system power-on messages.
  1. Confirm that you have connected cables to the SER MGT 0 ports on the two SPs located at the rear of the server.

    See Connect SP Cables.

  2. Connect terminals or a terminal emulators (PC or workstation) to the two serial connections.

    Configure the terminal or terminal emulator with these settings:

    Parameter
    Setting
    Connector
    SER MGT
    Rate
    9600 baud
    Parity
    None
    Stop bits
    1
    Data bits
    8

    where port pin signals are as follows, from left to right:

    Pin
    Signal Description
    Pin
    Signal Description
    1
    Request to Send
    5
    Ground
    2
    Data Terminal Ready
    6
    Receive Data
    3
    Transmit Data
    7
    Data Set Ready
    4
    Ground
    8
    Clear to Send
  3. Press the Enter or Return key on the terminal devices connected to the SPs.

    This action establishes the serial connections to the SER MGT 0 ports on the server.

  4. Continue with the installation by supplying power to the server for the first time.

    See Supply Power to the Server.

Related Information