Go to main content

SPARC T5-2 Server Service Manual

Exit Print View

Updated: February 2019
 
 

Component Service Categories

The server components and assemblies that can be replaced in the field fall into three categories:

  • Hot-service, replaceable by customer

  • Cold-service, replaceable by customer

  • Cold-service, replaceable by authorized service personnel

Cold service procedures require that you shut the server down and unplug the power cables that connect the power supplies to the power source.

Although hot service procedures can be performed while the server is running, you should usually bring it to standby mode as the first step in the replacement procedure. Refer to Power Off the Server (Power Button - Graceful) for instructions.

The following table identifies the components in each category.

Component service Category
Component
Service information
Notes
Hot-service, replaceable by customer
Drive
Drive must be offline.
Drive filler
Needed to preserve proper interior air flow.
Power supply
If two power supplies are in use. Otherwise, cold service.
Fan module
Removal of a fan in the rear row requires replacement within 30 seconds to avoid overheating
Cold-service, replaceable by customer
Memory risers and DIMMs
DVD drive
Remove any media prior to replacement.
A drive must be installed to preserve proper interior air flow.
System battery
I/O cards
Cold-service, replaceable by authorized service personnel
Fan board
Motherboard
Transfer system configuration PROM to new motherboard.
Drive backplane
PS backplane

Related Information