Rear Panel Controls and LEDs

image:Figure showing the rear panel controls and LEDs.
No.
LED
Icon or Label
Description
1
Power Supply AC OK LED
AC
Indicates these conditions:
  • Off – No AC power applied to this power supply.

  • Green steady on – AC power is applied to this power supply and is within specifications.

  • Amber steady on – AC power is applied to this power supply and is below 85V.

2
Power Supply DC OK LED
(green)
image:DC OK icon
Indicates these conditions:
  • Off – 12V DC output from this power supply is disabled or not within spec.

  • Steady on – 12V DC output from this power supply is present and within specifications.

3
Power Supply Fault LED
(amber)
image:Service action icon
Indicates these conditions:
  • Off – Steady state, no service action is required.

  • Steady on – A fault has been detected on this power supply

4
NET MGT Port Link/Activity LED
(green on left)
LINK/ACT
Indicates these conditions:
  • Off – No link is established.

  • Steady On – A link is established.

  • Blinking – A link is established and there is activity on the port.

4
NET MGT Port Speed LED
(green on right)
SPD
Indicates these conditions:
  • Off – The link is operating as a 10-Mbps connection.

  • Steady On – The link is operating as a 100-Mbps connection.

5
Locator LED and button
(white)
image:Icon for the Locator Button/LED
Turn on the Locator LED by pressing the Locator button, or see Locate the Server. When lit, the LED blinks rapidly.
6
Service Required LED
(amber)
image:Icon for the Service Required LED
The fmadm faulty command provides details about any faults that cause this indicator to light. See Check for Faults.
Under some fault conditions, individual component fault LEDs are lit in addition to the Service Required LED.
7
Power OK LED
(green)
image:Icon for the Power OK LED
Indicates these conditions:
  • Off – Server is not running in its normal state. System power might be off. The SP might be running.

  • Steady on – Server is powered on and is running in its normal operating state. No service actions are required.

  • Fast blink – Server is running in standby mode and can be quickly returned to full function.

  • Slow blink – A normal but transitory activity is taking place. Slow blinking might indicate that system diagnostics are running or that the system is booting.

8
Host Ethernet Port Link/Activity LED
(green)
These LEDs, from left to right, represent NET 1, NET 0, NET 3, and NET 2.
Indicates these conditions:
  • Off – No link is established.

  • Steady On – A link is established.

  • Blinking – A link is established and there is activity on the port.

Related Information