Verify Power Supply Functionality

  1. Verify that the amber Service Required LED on the replaced power supply is not lit.
  2. Verify that the PS Fault LED on the front of the server is not lit.
  3. Use the Oracle ILOM show faulty command to verify that the fault has been cleared.

    See Check for Faults for more information on using the show faulty command.

  4. Perform one of the following tasks based on your verification results:
    • If the previous steps did not clear the fault, see Detecting and Managing Faults for information about the tools and methods you can use to diagnose component faults.

    • If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required.