1 |
Locator LED and button
(white) |
|
You can turn on the Locator LED to identify
a particular server. When lit, the LED blinks rapidly. Turn on the
Locator LED by pressing the Locator button, or see Locate the Server. |
2 |
Service Required LED
(amber) |
|
The fmadm faulty command
provides details about any faults that cause this indicator to light.
See Check for Faults.
Under some fault conditions, individual component fault LEDs
are lit in addition to the Service Required LED. |
3 |
Power OK LED
(green) |
|
Indicates these conditions:
Off – Server
is not running in its normal state. Server power might be off. The
SP might be running.
Steady on – Server
is powered on and is running in its normal operating state. No service
actions are required.
Fast blink – Server
is running in standby mode and can be quickly returned to full function.
Slow blink – A
normal but transitory activity is taking place. Slow blinking might
indicate that server diagnostics are running or that the server
is booting.
|
4 |
Power button |
|
|
5 |
SP LED |
SP |
Indicates these conditions:
Off – AC
power might have been connected to the power supplies.
Steady on, green – SP
is running in its normal operating state. No service actions are
required.
Blink, green – SP
is initializing the Oracle ILOM firmware.
Steady on, amber – An
SP error has occurred and service is required.
|
6 |
Fan Module Fault LED
(amber) |
FAN |
Indicates these conditions:
Off – Steady
state, no service action is required.
Steady on – A
fan module failure event has been acknowledged and a service action
is required on at least one of the fan modules.
|
6 |
CPU Fault LED
(amber) |
CPU |
Indicates these conditions:
Off – Steady
state, no service action is required.
Steady on – A
fault has been detected on one or more host processors.
|
6 |
Memory Fault LED
(amber) |
MEM |
Indicates these conditions:
Off – Steady
state, no service action is required.
Steady on – A
fault has been detected on one or more DIMMs.
|
7 |
Power Supply Fault LED
(amber) |
PS |
Indicates these conditions:
Off – Steady
state, no service action is required.
Steady on – A
fault has been detected on one of the two power supplies
|
8 |
System Overtemp LED(amber) |
|
Indicates these conditions:
Off – Steady
state, no service action is required.
Steady on – A
temperature failure event has been acknowledged. A temperature limit
has been exceeded and a service action is required.
|