Remove the Battery


Caution

Caution  - This procedure requires that you handle components that are sensitive to ESD. This sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic practices as described in ESD Measures.


A customer can perform this procedure. The server must be completely powered down before performing this procedure. See Component Service Categories for more information about cold-service procedures.

  1. Prepare for servicing.
    1. Attach an antistatic wrist strap.
    2. Power off the server and unplug power cords from the power supplies.

      See Removing Power From the Server.

    3. Extend the server to maintenance position.

      See Extend the Server to the Service Position.

    4. Remove the top cover.

      See Remove the Top Cover.

  2. Gently push the battery toward the service processor to release it from the retention clip.
    image:Figure showing location of the battery.
  3. Install a new battery.

    See Install the Battery.

Related Information