Determine Which DIMM Is Faulty (FMA)

The FMA fmadm faulty command displays current server faults, including DIMM failures.

  • Type fmadm faulty at the faultmgmtsp prompt.
    -> start /SP/faultmgmt/shell
    Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
    
    faultmgmtsp> fmadm faulty
    ------------------- ------------------------------------ ---------------- ---------
    Time                UUID                                 msgid            Severity
    ------------------- ------------------------------------ ---------------- ---------
    2013-01-18/21:04:40 7040d859-5b03-4a58-8dfd-e3a80875d62f SPSUN4V-8000-CQ  MAJOR
    Problem Status : solved
    Diag Engine : fdd 1.0
    System
        Manufacturer     : Oracle Corporation
        Name             : SPARC T5-8
        Part_Number      : 12345678+11+1
        Serial_Number    : xxxxxxxxxx
    System Component
        Manufacturer     : Oracle Corporation
        Name             : SPARC T5-8
        Part_Number      : 12345678-+11+1
        Serial_Number    : xxxxxxxxxx
    --------------------------------------------
    Suspect 1 of 1
        Fault class      : fault.memory.dimm-ue
        Certainty        : 100%
        Affects          : /SYS/PM0/CM1/CMP/BOB0/CH0/D0
        Status           : faulted but still in service
    
        FRU
            Status       : faulty
            Location     : /SYS/PM0/CM1/CMP/BOB0/CH0/D0
            Manufacturer : Samsung
            Name         : 8192MB DDR3 SDRAM DIMM
            Part_Number  : 07042208,M393B1K70DH0-YK0
            Revision     : 04
            Serial_Number : 00CE02121585C74755
            Chassis
                Manufacturer    : Oracle Corporation
                Name            : T5 chassis
                Part_Number     : abcd
                Serial_Number   : dbca
    
    Description: The number of correctable errors associated with this memory
                 module has exceeded acceptable levels.
    
    Response   : An attempt will be made to remove the affected memory from
                 service.
    
    Impact     : The dimm may be deconfigured at system restart which would
                 reduce total system memory capacity.
    
    Action     : Use 'fmadm faulty' to provide a more detailed view of this
                 event. Please refer to the associated reference document at
                 http://support.oracle.com/msg/SPSUN4V-8000-CQ for the latest
                 service procedures and policies regarding this diagnosis.
    ---------------------------------------------------------------------------

Related Information