Go to main content

SPARC T5-8 Server Service Manual

Exit Print View

Updated: February 2019
 
 

Verify the Fan Module

  1. Ensure that you have completed the following:
  2. Check the front or rear panel LEDs for the following indications:
    • Green System OK LED – illuminated

    • Amber System Fault LED – not illuminated

    • Amber System Fan Fault LED – not illuminated

    See Front Panel Controls and LEDs and Rear Panel Controls and LEDs for the LED locations.

    If these conditions are not met, perform the actions described in Diagnostics Process.

  3. Log in to Oracle ILOM.

    See Log In to Oracle ILOM (Service).

  4. Start the faultmgmt shell.
    -> start SP/faultmgmt/shell
    Are you sure you want to start the faultmgmt shell (y/n)? y
    
    faultmgmtsp>
  5. Use the fmadm faulty command to determine if the server is operating normally.
    • If a fault was detected, see Diagnostics Process.

    • If no fault was detected, the fan module was installed successfully.

Related Information