Determine Which Processor Module Is Faulty

The following LEDs are lit when a processor module fault is detected:

  • Front and rear System Fault (Service Required) LEDs

  • Service Required LED on the faulty processor module


Note -  A faulty processor module at PM0 results in server shutdown and failure to reboot. If your server experiences a fault at PM0 and you do not have a replacement processor module available, you can move one of the other processor modules to PM0 and then boot the server in a degraded state.

Caution

Caution  -  In order to maintain system cooling, all four processor module slots must be occupied either with a processor module or a processor filler module.


  1. Determine if the Service Required LEDs are lit on the front panel or the rear I/O module.

    See Interpreting LEDs.

  2. From the front of the server, check the processor module LEDs to identify which processor module needs to be replaced.

    See Processor Module LEDs.

  3. Remove the faulty processor module.

    See Remove a Processor Module or Processor Filler Module.