Remove Fabric Interconnect F1-4 I/O Modules
When you are performing field replacement for one or more I/O Modules, make
sure to use the lock and unlocked positions appropriately—for example,
make sure that you lock the modules when you are done servicing them.
To remove a Fabric Interconnect F1-4 I/O module, follow this procedure:
-
When handling I/O modules, make sure that you are using ESD safety
precautions, such as a grounding strap that is properly attached to an earth
ground source.
-
Before removing an I/O module, use the XgOS to shutdown the I/O module.
-
Using a slotted screwdriver, unlock the I/O module by turning it 90
degrees counterclockwise. See (1) in Removing a Fabric Interconnect F1-4 I/O Module.
Figure 93 Removing a Fabric Interconnect F1-4 I/O Module
-
Grasp the module handle and remove the I/O module, while keeping the
module level (2) as shown in Removing a Fabric Interconnect F1-4 I/O Module.