Name

tt_spec_bprop - retrieve the ith value of a property

Synopsis

#include <Tt/tt_c.h>
Tt_status tt_spec_bprop(const char *objid,
const char *propname,
int i,
unsigned char **value,
int *length);

Description

tt_spec_bprop(3)              ToolTalk Functions              tt_spec_bprop(3)



NAME
       tt_spec_bprop - retrieve the ith value of a property

SYNOPSIS
       #include <Tt/tt_c.h>
       Tt_status tt_spec_bprop(const char *objid,
                               const char *propname,
                               int i,
                               unsigned char **value,
                               int *length);

DESCRIPTION
       The  tt_spec_bprop()  function retrieves the ith value of the specified
       property.

       The objid argument is the identifier of the  object  involved  in  this
       operation.   The  propname  argument  is the name of the property whose
       value is to be retrieved.  The name must be less  than  64  characters.
       The  i  argument  is  the  item  of the list for which a value is to be
       obtained.  The list numbering begins with zero.  The value argument  is
       the  address of a character pointer to which the ToolTalk service is to
       point a string that contains the contents of the spec's  property.   If
       there  are  i  values or fewer, the pointer is set to zero.  The length
       argument is the address of an integer to which the ToolTalk service  is
       to set the length of the value in bytes.

RETURN VALUE
       Upon  successful  completion,  the tt_spec_bprop() function returns the
       status of the operation as one of the following Tt_status values:

          TT_OK   The operation completed successfully.

          TT_ERR_NOMP
                  The ttsession(1) process is not  running  and  the  ToolTalk
                  service cannot restart it.

          TT_ERR_NUM
                  The integer value passed was invalid (out of range).

          TT_ERR_OBJID
                  The  objid passed to the ToolTalk service does not reference
                  an existing object spec.

          TT_ERR_PROPNAME
                  The specified property name is syntactically invalid.

ATTRIBUTES
       See attributes(7) for descriptions of the following attributes:


       +---------------+------------------+
       |ATTRIBUTE TYPE | ATTRIBUTE VALUE  |
       +---------------+------------------+
       |Availability   | library/tooltalk |
       +---------------+------------------+
       |Stability      | Committed        |
       +---------------+------------------+

SEE ALSO
       tt_c(5).