Install a Fan Module (CMIOU Chassis)


Caution  -  If you remove this component while the server is powered on, wait 30 seconds before installing the replacement component. Doing so ensures that Oracle ILOM has enough time to detect the new component, which is required for the software to power it on.


  1. Insert the new fan module into the empty fan slot.
  2. Push the fan module into the slot until it clicks into place to completely seat the module into the slot.
  3. Power on the server, if necessary.

    If the server was powered off when you installed the new fan module, see Returning the Server to Operation.

  4. Verify that the fault has been cleared and the replaced component is operational.

    See Verify That a Fault Has Been Cleared.

  5. Return the replaced component to Oracle.

    See Prepare a Component for Return to Oracle.