Go to main content

SPARC M8 and SPARC M7 Servers Service Manual

Exit Print View

Updated: January 2022
 
 

Index

Numbers and Symbols

/var/adm/messages fileindex iconView Log Files (Oracle Solaris)

A

AC inputs
installingindex iconInstall a Power Module
locating
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
removingindex iconRemove a Power Module
AC Power OK LEDindex iconRear Indicator Panel Controls and LEDs
Active SP
changing to Standby SPindex iconChange Which SP Is Managing System Activity
describedindex iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (One PDomain)
identifyingindex iconDetermine Which SP Is Managing System Activity
antistatic wrist strapindex iconAttach an Antistatic Wrist Strap

B

batteries
installingindex iconInstall the Battery
locationindex iconRemove the Battery
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removingindex iconRemove the Battery
SDM nameindex iconComponent Service Task Reference
BUS names
identifying for root complex assignmentindex iconUnderstanding PCIe Card Device and Service Paths

C

clear_fault_action propertyindex iconComponent Oracle ILOM State Properties
clearing faultsindex iconClear a Fault Manually
CMIOU chassis
installingindex iconInstall a CMIOU Chassis
removingindex iconRemove a CMIOU Chassis
CMIOUs
configuration reference
SPARC M7-16index iconCMIOU Configurations (SPARC M7-16)
SPARC M7-8 (one PDomain)index iconCMIOU Configurations (SPARC M8-8 and SPARC M7-8 With One PDomain)
SPARC M7-8 (two PDomains)index iconCMIOU Configurations (SPARC M8-8 and SPARC M7-8 With Two PDomains)
fault toleranceindex iconComponent Fault Tolerances
installingindex iconInstall a CMIOU
LEDsindex iconCMIOU Indicators and LEDs
locatingindex iconCMIOU Chassis Rear Components
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
preparing for removalindex iconPrepare a CMIOU for Removal
removingindex iconRemove a CMIOU
reseatingindex iconReseat a CMIOU
returning to Oracleindex iconReturn a CMIOU to Oracle
SDM nameindex iconComponent Service Task Reference
unseatingindex iconUnseat a CMIOU
CMPs, name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
CMs, name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
commands
Oracle ILOM referenceindex iconOracle ILOM Service-Related Tools
power_stateindex iconCheck the Power State of the Server or Host (Oracle ILOM)
prepare_to_removeindex iconPrepare a Component for Removal
return_to_serviceindex iconReturn a Component to Service
components
A/C power status requirements for removalindex iconComponent Service Categories
accessible from front
SPARC M7-16index iconServer Front Components (SPARC M7-16)
SPARC M7-8index iconServer Front Components (SPARC M8-8 and SPARC M7-8 Servers)
SPARC M8-8index iconServer Front Components (SPARC M8-8 and SPARC M7-8 Servers)
accessible from rear
SPARC M7-16index iconServer Rear Components (SPARC M7-16)
SPARC M7-8 serversindex iconServer Rear Components (SPARC M8-8 and SPARC M7-8 Servers)
SPARC M8-8 serversindex iconServer Rear Components (SPARC M8-8 and SPARC M7-8 Servers)
authorized personnel required for serviceindex iconComponent Service Categories
DIMMsindex iconDIMM Configuration
LED referenceindex iconComponent-Specific LEDs
names returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
paths used to serviceindex iconComponent Service Task Reference
preparing for removalindex iconPrepare a Component for Removal
returning to Oracleindex iconPrepare a Component for Return to Oracle
returning to serviceindex iconReturn a Component to Service
serviceability referenceindex iconComponent Service Categories
state propertiesindex iconComponent Oracle ILOM State Properties
configuration reference
CMIOUs
SPARC M7-16index iconCMIOU Configurations (SPARC M7-16)
SPARC M7-8 (one PDomain)index iconCMIOU Configurations (SPARC M8-8 and SPARC M7-8 With One PDomain)
SPARC M7-8 (two PDomains)index iconCMIOU Configurations (SPARC M8-8 and SPARC M7-8 With Two PDomains)
DIMMsindex iconDIMM Configuration
external interconnect assembliesindex iconExternal Interconnect Assembly Configuration
internal interconnect assembliesindex iconInternal Interconnect Assembly Configuration
PCIe slotsindex iconPCIe Card Slot Configuration and Numbering
configurations
I/O cards
restoringindex iconRestore a PCIe Card Configuration on an I/O Domain
savingindex iconPrepare a PCIe Card For Removal
configuring
POSTindex iconConfigure POST
connecting to host consoleindex iconRestart the Server or Host (Oracle ILOM)
cooling
power supplies requiredindex iconServicing Power Supplies
zonesindex iconUnderstanding Server Cooling Zones
current_config_state propertyindex iconComponent Oracle ILOM State Properties

D

DCU SPM
describedindex iconSPARC M7-16 Configurations and Failover Behavior
identifyingindex iconDetermine Which SPP Is Managing DCU Activity (SPARC M7-16)
DCUs
describedindex iconUnderstanding Server Configurations and Failover Behavior
DIMMs
configurationindex iconDIMM Configuration
failuresindex iconDetermine Which DIMM Is Faulty (Oracle ILOM)
Fault Remind buttonindex iconDetermine Which DIMM Is Faulty (LEDs)
fault toleranceindex iconComponent Fault Tolerances
general error messageindex iconDIMM Configuration Fault Messages
installingindex iconInstall a DIMM
locatingindex iconDIMM and eUSB Locations in a CMIOU
locating faulty
using DIMM Fault Remind buttonindex iconDetermine Which DIMM Is Faulty (LEDs)
using Oracle ILOMindex iconDetermine Which DIMM Is Faulty (Oracle ILOM)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
naming or labelingindex iconDIMM Names
orientationindex iconInstall a DIMM
removingindex iconRemove a DIMM
SDM nameindex iconComponent Service Task Reference
slots populatedindex iconDIMM Configuration
disabled components
detecting with Oracle ILOMindex iconIdentify Disabled Components
names returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
dmesg commandindex iconDisplay Fault Diagnostics (Message Buffer)
domains  Seeindex iconPDomains

E

electrostatic discharge  Seeindex iconESD
ESD
preventingindex iconPrevent ESD Damage
wrist strapindex iconAttach an Antistatic Wrist Strap
eUSB disks
installingindex iconInstall an eUSB Disk
locatingindex iconDIMM and eUSB Locations in a CMIOU
removingindex iconRemove an eUSB Disk
external interconnect assemblies
configuration referenceindex iconExternal Interconnect Assembly Configuration
installingindex iconInstall an External Interconnect Assembly
locatingindex iconSwitch Chassis Front Components (SPARC M7-16)
removingindex iconRemove an External Interconnect Assembly
slot numbersindex iconSwitch Chassis Front Components (SPARC M7-16)

F

fan cable assemblies
installingindex iconInstall a Fan Cable Assembly
removingindex iconRemove a Fan Cable Assembly
fan modules
fault toleranceindex iconComponent Fault Tolerances
installing
in CMIOU chassisindex iconInstall a Fan Module (CMIOU Chassis)
in switch chassisindex iconInstall a Fan Module (Switch Chassis)
LEDs
in CMIOU chassisindex iconFan LEDs (CMIOU Chassis)
in switch chassisindex iconFan Module LED (Switch Chassis)
locating
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removing
in CMIOU chassisindex iconRemove a Fan Module (CMIOU Chassis)
in switch chassisindex iconRemove a Fan Module (Switch Chassis)
SDM nameindex iconComponent Service Task Reference
fault detection
names returnedindex iconComponent Names Displayed by Diagnostic Software
overview of methodsindex iconChecking for Faults
with Oracle ILOMindex iconIdentify Faulted Components
fault_state propertyindex iconComponent Oracle ILOM State Properties
firmwareindex iconSP Firmware and Configuration
fmadm faulty command
index iconClear a Fault Manually
index iconIdentify Faulted Components
fmadm commandindex iconClear a Fault Manually
FPGAs
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
front components
SPARC M7-16index iconServer Front Components (SPARC M7-16)
SPARC M7-8index iconServer Front Components (SPARC M8-8 and SPARC M7-8 Servers)
SPARC M8-8index iconServer Front Components (SPARC M8-8 and SPARC M7-8 Servers)
front indicator panel cables
installingindex iconInstall the Front Indicator Panel Cable
removingindex iconRemove the Front Indicator Panel Cable
front indicator panels
installingindex iconInstall a Front Indicator Panel
locating
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removingindex iconRemove a Front Indicator Panel
front panel system controls and LEDsindex iconFront Indicator Panel Controls and LEDs

H

host console, connecting toindex iconRestart the Server or Host (Oracle ILOM)
hosts
powering offindex iconPower Off the Server or Domain (Oracle ILOM)
powering onindex iconRestart the Server or Host (Oracle ILOM)

I

I/O
card configurations
restoringindex iconRestore a PCIe Card Configuration on an I/O Domain
savingindex iconPrepare a PCIe Card For Removal
installation guidelines
DIMMsindex iconDIMM Configuration
PCIe cardsindex iconPCIe Card Installation Order Guidelines
installing
AC inputsindex iconInstall a Power Module
antistatic wrist strapindex iconAttach an Antistatic Wrist Strap
batteriesindex iconInstall the Battery
CMIOU chassisindex iconInstall a CMIOU Chassis
CMIOUsindex iconInstall a CMIOU
DIMMsindex iconInstall a DIMM
eUSB disksindex iconInstall an eUSB Disk
external interconnect assembliesindex iconInstall an External Interconnect Assembly
fan cable assembliesindex iconInstall a Fan Cable Assembly
fan modules
in CMIOU chassisindex iconInstall a Fan Module (CMIOU Chassis)
in switch chassisindex iconInstall a Fan Module (Switch Chassis)
front indicator panel cablesindex iconInstall the Front Indicator Panel Cable
front indicator panelsindex iconInstall a Front Indicator Panel
internal interconnect assembliesindex iconInstall an Internal Interconnect Assembly
PCIe card carriersindex iconInstall a Card Carrier Into the Server
PCIe cardsindex iconInstall a PCIe Card Into a Card Carrier
PDECBsindex iconInstall a PDECB
PDUsindex iconInstall a PDU
power modulesindex iconInstall a Power Module
power suppliesindex iconInstall a Power Supply
rear indicator panelsindex iconInstall a Power Module
SP internal interconnect assembliesindex iconInstall an SP Internal Interconnect Assembly
SP traysindex iconReseat or Install an SP Tray
SPPsindex iconInstall an SP or SPP
SPsindex iconInstall an SP or SPP
switch chassisindex iconInstall a Switch Chassis
switch unitsindex iconInstall a Switch Unit
internal interconnect assemblies
configuration referenceindex iconInternal Interconnect Assembly Configuration
installingindex iconInstall an Internal Interconnect Assembly
locatingindex iconCMIOU Chassis Front Components
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removingindex iconRemove an Internal Interconnect Assembly
slot numbersindex iconCMIOU Chassis Front Components

L

labels
of DIMMsindex iconDIMM Names
of interconnect slots
SPARC M7-16index iconSwitch Chassis Front Components (SPARC M7-16)
SPARC M7-8index iconCMIOU Chassis Front Components
SPARC M8-8index iconCMIOU Chassis Front Components
of PCIe slotsindex iconPCIe Card Slot Configuration and Numbering
LEDs
CMIOUsindex iconCMIOU Indicators and LEDs
component specific referenceindex iconComponent-Specific LEDs
fan modules
in CMIOU chassisindex iconFan LEDs (CMIOU Chassis)
in switch chassisindex iconFan Module LED (Switch Chassis)
front panelindex iconFront Indicator Panel Controls and LEDs
PCIe card carriersindex iconPCIe Card Carrier LEDs and Controls
power suppliesindex iconPower Supply LEDs
rear panelindex iconRear Indicator Panel Controls and LEDs
SPsindex iconSP General Status LEDs
switch unitsindex iconSwitch Unit LEDs
System Locatorindex iconFront Indicator Panel Controls and LEDs
System Overtempindex iconFront Indicator Panel Controls and LEDs
System Power OKindex iconFront Indicator Panel Controls and LEDs
System Service Requiredindex iconFront Indicator Panel Controls and LEDs
locating
AC inputs
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
batteriesindex iconRemove the Battery
CMIOUsindex iconCMIOU Chassis Rear Components
DIMMsindex iconDIMM and eUSB Locations in a CMIOU
eUSB disksindex iconDIMM and eUSB Locations in a CMIOU
external interconnect assembliesindex iconSwitch Chassis Front Components (SPARC M7-16)
fan modules
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
faults
with Oracle ILOMindex iconIdentify Faulted Components
faulty DIMMs
using Fault Remind buttonindex iconDetermine Which DIMM Is Faulty (LEDs)
using Oracle ILOMindex iconDetermine Which DIMM Is Faulty (Oracle ILOM)
front indicator panels
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
internal interconnect assembliesindex iconCMIOU Chassis Front Components
PCIe card carriersindex iconCMIOU Chassis Rear Components
PCIe cardsindex iconLocate a PCIe Card in the Server
PDECBs
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
power supplies
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
rear indicator panels
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
serverindex iconLocate the Server
SP internal interconnect assemblies
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
SP trays
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
SPs
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
switch unitsindex iconSwitch Chassis Rear Components (SPARC M7-16)
Locator LED
lightingindex iconLocate the Server
log files, viewingindex iconView Log Files (Oracle Solaris)
logging in to Oracle ILOMindex iconLog In to Oracle ILOM (Service)

M

message buffer, checking theindex iconDisplay Fault Diagnostics (Message Buffer)
message identifierindex iconIdentify Faulted Components

N

NAC path referenceindex iconComponent Names Displayed by Diagnostic Software
names
of DIMMsindex iconDIMM Names
of interconnect slots
SPARC M7-16index iconSwitch Chassis Front Components (SPARC M7-16)
SPARC M7-8index iconCMIOU Chassis Front Components
SPARC M8-8index iconCMIOU Chassis Front Components
of PCIe slotsindex iconPCIe Card Slot Configuration and Numbering
naming conventions
NAC component referenceindex iconComponent Names Displayed by Diagnostic Software
SDM component referenceindex iconComponent Service Task Reference
NET MGT ports
locations and numberingindex iconSER MGT and NET MGT Port Locations and Numbering
numbering
of interconnect slots
SPARC M7-16index iconSwitch Chassis Front Components (SPARC M7-16)
SPARC M7-8index iconCMIOU Chassis Front Components
SPARC M8-8index iconCMIOU Chassis Front Components
of NET MGT portsindex iconSER MGT and NET MGT Port Locations and Numbering
of PCIe slotsindex iconPCIe Card Slot Configuration and Numbering
of SER MGT portsindex iconSER MGT and NET MGT Port Locations and Numbering

O

Oracle ILOM
command referenceindex iconOracle ILOM Service-Related Tools
component state propertiesindex iconComponent Oracle ILOM State Properties
identifying
disabled componentsindex iconIdentify Disabled Components
faulted componentsindex iconIdentify Faulted Components
logging in toindex iconLog In to Oracle ILOM (Service)
SPM pathsindex iconOracle ILOM Paths for SPMs
Oracle Solaris
clearing faultsindex iconClear a Fault Manually

P

packing components for return to Oracleindex iconPrepare a Component for Return to Oracle
PCIe card carriers
installingindex iconInstall a Card Carrier Into the Server
LEDsindex iconPCIe Card Carrier LEDs and Controls
locatingindex iconCMIOU Chassis Rear Components
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
numberingindex iconPCIe Card Slot Configuration and Numbering
removingindex iconRemove a PCIe Card Carrier and Card From the Server
supportedindex iconSupported PCIe Card Carriers and PCIe Cards
PCIe cards
BUS names, for root complex assignmentindex iconUnderstanding PCIe Card Device and Service Paths
characteristicsindex iconPCIe Card Slot Configuration and Numbering
configurations
restoringindex iconRestore a PCIe Card Configuration on an I/O Domain
savingindex iconPrepare a PCIe Card For Removal
device and service path referenceindex iconUnderstanding PCIe Card Device and Service Paths
fault toleranceindex iconComponent Fault Tolerances
installation orderindex iconPCIe Card Installation Order Guidelines
installingindex iconInstall a PCIe Card Into a Card Carrier
locatingindex iconLocate a PCIe Card in the Server
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
preparing for removalindex iconPrepare a PCIe Card For Removal
SDM nameindex iconComponent Service Task Reference
supportedindex iconSupported PCIe Card Carriers and PCIe Cards
verifying functionalityindex iconVerify the PCIe Card
PCIe slots, configuration referenceindex iconPCIe Card Slot Configuration and Numbering
PDECBs
installingindex iconInstall a PDECB
locating
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removingindex iconRemove a PDECB
SDM nameindex iconComponent Service Task Reference
PDomain SPM
changing to Standby SPMindex iconChange Which SPP Is Managing DCU Activity (SPARC M7-16)
describedindex iconSPARC M7-16 Configurations and Failover Behavior
PDomains
describedindex iconUnderstanding Server Configurations and Failover Behavior
powering offindex iconPower Off the Server or Domain (Oracle ILOM)
powering onindex iconRestart the Server or Host (Oracle ILOM)
static, describedindex iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (Two PDomains)
PDU circuit breakers
switching offindex iconSwitch Off PDU Circuit Breakers
switching onindex iconSwitch on PDU Circuit Breakers
PDUs
AC connectionsindex iconPDU and AC Connections
installingindex iconInstall a PDU
preparing for removalindex iconPrepare a PDU for Removal
removingindex iconRemove a PDU
POST
configuration examplesindex iconConfigure POST
configuringindex iconConfigure POST
overviewindex iconPOST Overview
power
redundancyindex iconPDU and AC Connections
removingindex iconRemoving Power From the Server or Domain
restoringindex iconReturning the Server to Operation
power modules
installingindex iconInstall a Power Module
removingindex iconRemove a Power Module
power supplies
fault toleranceindex iconComponent Fault Tolerances
installingindex iconInstall a Power Supply
LEDsindex iconPower Supply LEDs
locating
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
number required for coolingindex iconServicing Power Supplies
removingindex iconRemove a Power Supply
SDM nameindex iconComponent Service Task Reference
power_state commandindex iconCheck the Power State of the Server or Host (Oracle ILOM)
powering off
with Oracle ILOMindex iconPower Off the Server or Domain (Oracle ILOM)
with PDU circuit breakersindex iconSwitch Off PDU Circuit Breakers
powering onindex iconCheck the Power State of the Server or Host (Oracle ILOM)
with Oracle ILOMindex iconRestart the Server or Host (Oracle ILOM)
with PDU circuit breakersindex iconSwitch on PDU Circuit Breakers
prepare_to_remove commandindex iconPrepare a Component for Removal
preparing for removal
CMIOUsindex iconPrepare a CMIOU for Removal
PCIe cardsindex iconPrepare a PCIe Card For Removal
PDUsindex iconPrepare a PDU for Removal
SPPsindex iconPrepare to Remove an SPP (SPARC M7-16)
SPsindex iconPrepare to Remove an SP
switch unitsindex iconPrepare a Switch Unit for Removal

R

rear components
SPARC M7-16index iconServer Rear Components (SPARC M7-16)
SPARC M7-8index iconServer Rear Components (SPARC M8-8 and SPARC M7-8 Servers)
SPARC M8-8index iconServer Rear Components (SPARC M8-8 and SPARC M7-8 Servers)
Rear Fault LEDindex iconFront Indicator Panel Controls and LEDs
rear indicator panels
installingindex iconInstall a Power Module
locating
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removingindex iconRemove a Power Module
rear panel system controls and LEDsindex iconRear Indicator Panel Controls and LEDs
redundancy
of powerindex iconPDU and AC Connections
on SPARC M7-8 (two PDomains)index iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (Two PDomains)
on SPARC M8-8 (two PDomains)index iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (Two PDomains)
removing
AC inputsindex iconRemove a Power Module
batteriesindex iconRemove the Battery
CMIOU chassisindex iconRemove a CMIOU Chassis
CMIOUsindex iconRemove a CMIOU
DIMMsindex iconRemove a DIMM
eUSB disksindex iconRemove an eUSB Disk
external interconnect assembliesindex iconRemove an External Interconnect Assembly
fan cable assembliesindex iconRemove a Fan Cable Assembly
fan modules
in CMIOU chassisindex iconRemove a Fan Module (CMIOU Chassis)
in switch chassisindex iconRemove a Fan Module (Switch Chassis)
front indicator panel cablesindex iconRemove the Front Indicator Panel Cable
front indicator panelsindex iconRemove a Front Indicator Panel
internal interconnect assembliesindex iconRemove an Internal Interconnect Assembly
PCIe card carriersindex iconRemove a PCIe Card Carrier and Card From the Server
PDECBsindex iconRemove a PDECB
PDUsindex iconRemove a PDU
power modulesindex iconRemove a Power Module
power suppliesindex iconRemove a Power Supply
rear indicator panelsindex iconRemove a Power Module
SP internal interconnect assembliesindex iconRemove an SP Internal Interconnect Assembly
SP traysindex iconUnseat or Remove an SP Tray
SPPsindex iconRemove an SP or SPP
SPsindex iconRemove an SP or SPP
switch chassisindex iconRemove a Switch Chassis
switch unitsindex iconRemove a Switch Unit
requested_config_state propertyindex iconComponent Oracle ILOM State Properties
reseating
CMIOUsindex iconReseat a CMIOU
SP traysindex iconReseat or Install an SP Tray
switch unitsindex iconReseat a Switch Unit
restoring I/O card configurationsindex iconRestore a PCIe Card Configuration on an I/O Domain
return_to_service commandindex iconReturn a Component to Service
returning componentsindex iconPrepare a Component for Return to Oracle
returning components to serviceindex iconReturn a Component to Service
root complexes, BUS names to assignindex iconUnderstanding PCIe Card Device and Service Paths

S

safety information and symbolsindex iconSafety Information
saving I/O card configurationsindex iconPrepare a PCIe Card For Removal
SDM path referenceindex iconComponent Service Task Reference
SER MGT ports
locations and numberingindex iconSER MGT and NET MGT Port Locations and Numbering
serial number
identifyingindex iconFind the Server Serial Number
server
lighting Locator LEDindex iconLocate the Server
PDU circuit breakers
switching offindex iconSwitch Off PDU Circuit Breakers
switching onindex iconSwitch on PDU Circuit Breakers
powering offindex iconPower Off the Server or Domain (Oracle ILOM)
powering on
index iconCheck the Power State of the Server or Host (Oracle ILOM)
index iconRestart the Server or Host (Oracle ILOM)
serial number, identifyingindex iconFind the Server Serial Number
show disabled commandindex iconIdentify Disabled Components
slot numbers
external interconnect assemblies
SPARC M7-16index iconSwitch Chassis Front Components (SPARC M7-16)
interconnect assemblies
SPARC M7-8index iconCMIOU Chassis Front Components
SPARC M8-8index iconCMIOU Chassis Front Components
SP internal interconnect assemblies
CMIOU chassis
slot numbersindex iconCMIOU Chassis Front Components
installingindex iconInstall an SP Internal Interconnect Assembly
locating
in CMIOU chassisindex iconCMIOU Chassis Front Components
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
removingindex iconRemove an SP Internal Interconnect Assembly
slot numbers
in switch chassisindex iconSwitch Chassis Front Components (SPARC M7-16)
SP trays
locating
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
reseating or installingindex iconReseat or Install an SP Tray
unseating or removingindex iconUnseat or Remove an SP Tray
SPDBs
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
SPMs
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
paths supplied to Oracle ILOMindex iconOracle ILOM Paths for SPMs
verifying removal preparednessindex iconPrepare to Remove an SP
SPPs
installingindex iconInstall an SP or SPP
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
preparing for removalindex iconPrepare to Remove an SPP (SPARC M7-16)
removingindex iconRemove an SP or SPP
SDM nameindex iconComponent Service Task Reference
SPs
Active and Standby, describedindex iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (One PDomain)
fault toleranceindex iconComponent Fault Tolerances
installingindex iconInstall an SP or SPP
LEDsindex iconSP General Status LEDs
locating
in CMIOU chassisindex iconCMIOU Chassis Rear Components
in switch chassisindex iconSwitch Chassis Rear Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
preparing for removalindex iconPrepare to Remove an SP
removingindex iconRemove an SP or SPP
SDM nameindex iconComponent Service Task Reference
Standby SP
function ofindex iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (One PDomain)
static PDomains
describedindex iconSPARC M8-8 and SPARC M7-8 Configurations and Failover Behavior (Two PDomains)
storage devicesindex iconSupported Storage Devices
switch chassis
installingindex iconInstall a Switch Chassis
removingindex iconRemove a Switch Chassis
switch units
fault toleranceindex iconComponent Fault Tolerances
installingindex iconInstall a Switch Unit
LEDsindex iconSwitch Unit LEDs
locatingindex iconSwitch Chassis Rear Components (SPARC M7-16)
name returned by Oracle ILOMindex iconComponent Names Displayed by Diagnostic Software
preparing for removalindex iconPrepare a Switch Unit for Removal
removingindex iconRemove a Switch Unit
reseatingindex iconReseat a Switch Unit
SDM nameindex iconComponent Service Task Reference
unseatingindex iconUnseat a Switch Unit
system controls, front panelindex iconFront Indicator Panel Controls and LEDs
system controls, rear panelindex iconRear Indicator Panel Controls and LEDs
System Locator LEDindex iconFront Indicator Panel Controls and LEDs
system message log files, viewingindex iconView Log Files (Oracle Solaris)
System Overtemp LEDindex iconFront Indicator Panel Controls and LEDs
System Power OK LEDindex iconFront Indicator Panel Controls and LEDs
System Service Required LEDindex iconFront Indicator Panel Controls and LEDs

T

tools needed for serviceindex iconTools Needed for Service

U

unseating
CMIOUsindex iconUnseat a CMIOU
SP traysindex iconUnseat or Remove an SP Tray
switch unitsindex iconUnseat a Switch Unit

V

verifying
fault removalindex iconVerify That a Fault Has Been Cleared
PCIe card functionalityindex iconVerify the PCIe Card
PCIe cards are offlineindex iconPrepare to Remove an SPP (SPARC M7-16)
SPM removal preparednessindex iconPrepare to Remove an SP
viewing
system message log filesindex iconView Log Files (Oracle Solaris)

W

wrist strap, installingindex iconAttach an Antistatic Wrist Strap