Slide the new cable through the opening in the chassis where the failed cable was previously
installed.
-
Insert the four panel mount connectors through each of the receiving tabs and slide the black
tab to the left to secure it.
-
Screw the top bracket of the cable assembly to the chassis.
-
Reinstall the interconnects in the same slots from which you removed them.
See Servicing Internal Interconnect Assemblies, Servicing External Interconnect Assemblies (SPARC M7-16), and Servicing SP Internal Interconnect Assemblies.
-
Reseat the SP tray.
See Reseat or Install an SP Tray.
-
Reseat the CMIOUs.
See Reseat a CMIOU.
-
Reinstall the fans in the same slots from which you removed them.
See Install a Fan Module (CMIOU Chassis) or
Install a Fan Module (Switch Chassis).
-
Switch on the appropriate PDU circuit breakers and power on the server.
Returning the Server to Operation.
-
Verify that the fault has been cleared and the replaced component is
operational.
See Verify That a Fault Has Been Cleared.
-
Return the replaced component to Oracle.
See Prepare a Component for Return to Oracle.