Skip Navigation Links
Sun Network QDR InfiniBand Gateway Switch HTML Document Collection for Firmware Version 2.1
Search Scope:
This Document
Entire Library
Sun Network QDR InfiniBand Gateway Switch HTML Document Collection for Firmware Version 2.1
March 2013, Revision A
Browse the combined installation, administration, and service documentation.
Document Information
Using This Documentation
Product Notes
Related Documentation
Feedback
Access to Oracle Support
Installation
Understanding the Gateway
Gateway Overview
Physical Specifications
Environmental Requirements
Acoustic Noise Emissions
Electrical Specifications
NET MGT Connector and Pins
USB Management Connector and Pins
Data QSFP Connector and Pins
Understanding Cabling
Routing Service Cables
Power Cord Requirements
Management Cable Requirements
Understanding Data Cabling
Data Cable Cautions
Data Cable Guidelines
Data Cable Types
Data Cable Path Lengths
Data Cable Bundling
Floor and Underfloor Delivery of Data Cables
Overhead Delivery of Data Cables
Preparing to Install the Gateway
Installation Preparation
Suggested Tools for Installation
Antistatic Precautions for Installation
Installation Responsibilities
Installation Sequence
Verify Shipping Carton Contents
Assemble the Optical Fiber Data Cables
Route the Data Cables
Installing the Gateway
Install the Gateway in the Rack
Powering On the Gateway
Attach the Management Cables
Attach the Power Cords
Accessing the Management Controller
Access the Management Controller From the NET MGT Port
Access the Management Controller From the USB Management Port
Verify the Gateway Status
Start the Subnet Manager
Connecting Data cables
Attach the Data Cables
Check Link Status
Verifying the InfiniBand Fabric
InfiniBand Node Description
Discover the InfiniBand Fabric Topology
Perform Diagnostics on the InfiniBand Fabric
Administration
Troubleshooting the Gateway
Gateway Hardware Problems
InfiniBand Fabric Problems
Network Management Troubleshooting Guidelines
Understanding Routing Through the Gateway
Switch Chip Port to QSFP Connectors and Link LED Routes
QSFP Connectors and Link LEDs to Switch Chip Port Routes
Signal Route Through the Gateway
Switch GUIDs Overview
Understanding Administrative Commands
Configuration Overview
Oracle ILOM Command Overview
Hardware Command Overview
InfiniBand Command Overview
Administering the Chassis
Monitoring the Chassis
Display Gateway General Health
Display Power Supply Status
Check Board-Level Voltages
Display Internal Temperatures
Display Fan Status
Display Gateway Environmental and Operational Data
Display Flash Drive Information
Display Free Memory and File System Space
Display Chassis FRU ID
Display Power Supply FRU ID
Display Gateway Firmware Versions
Oracle Auto Service Request
Controlling the Chassis
Restart the Management Controller
Change the
root
User Password
Administering the I4 Switch Chip
Monitoring the I4 Switch Chip
Display the Switch Chip Port to QSFP Connector Mapping
Locate a InfiniBand Device and Connector From the GUID and Port
Locate a Switch Chip or Connector From the GUID and Port
Display Switch Chip Boot Status
Display Link Status
Display Connectors Configured With Autodisable Functionality
Display Switch Chip Port Status
Display Switch Chip Port Counters
Controlling the I4 Switch Chip
Disable a Switch Chip Port
Enable a Switch Chip Port
Autodisabling Ports and Connectors
Autodisable Functionality
Add Connectors to the Autodisable List
Reenable Autodisabled Connectors
Delete Connectors From the Autodisable List
Administering the Subnet Manager
Monitoring the Subnet Manager
Display Subnet Manager Status
Display the Subnet Manager's Location History
Display Subnet Manager Priority, Controlled Handover State, Prefix, Management Key, and Routing Algorithm
Display the Secret M_Key Configuration
Verify M_Key Persistence
Verify the Subnet Manager Configuration Integrity
Display the Subnet Manager Log
Controlling the Subnet Manager
Set the Subnet Manager Priority
Set the Subnet Manager Prefix
Enable Subnet Manager Controlled Handover
Set the Subnet Manager Readable Management Key
Clear the Subnet Manager Readable Management Key
Set the Subnet Manager Routing Algorithm
Enable the Subnet Manager
Disable the Subnet Manager
Configuring Secure Fabric Management
Secret M_Key Overview
smsubnetprotection
Command
Prepare for Secret M_Key Functionality
Configuring Secret M_Keys
Create the Secret M_Key Configuration
Add Secret M_Keys to the Configuration
Set the Secret M_Key to Use
Delete Secret M_Keys From the Configuration
Configure a Local Secret M_Key
Set the Replication Password
Enable or Disable Secret M_Key Persistence
Enable or Disable Secret M_Key Functionality
Considering Situations In Regard to Secret M_Key
Add a New Subnet Manager to the Secret M_Key Fabric
Merge Subnets Into One Secret M_Key Fabric
Secret M_Key and Firmware Upgrade and Downgrade Guidelines
Administering the InfiniBand Fabric
Monitoring the InfiniBand Fabric
Displaying Information About Nodes
Identify All Switches in the Fabric
Identify All CAs in the Fabric
Display the InfiniBand Fabric Topology (Simple)
Display the InfiniBand Fabric Topology (Detailed)
Display a Route Through the Fabric
Display the Link Status of a Node
Display Counters for a Node
Display Low-Level Detailed Information About a Node
Display Low-Level Detailed Information About a Port
Displaying Fabric Functionality Configuration Information
Display the InfiniBand Fabric Partition Configuration
Display the InfiniBand Fabric Configuration
Display the
smnode
s List
Display the Fabric Element Configuration
Display the IPoIB Interface
Display Configured Secret M_Keys
Controlling the InfiniBand Fabric
Investigating Nodes
Perform Comprehensive Diagnostics for the Entire Fabric
Determine Changes to the InfiniBand Fabric Topology
Find 1x, SDR, or DDR Links in the Fabric
Determine Which Links Are Experiencing Significant Errors
Controlling Nodes
Clear Data and Error Counters
Reset a Port
Set Port Speed
Disable or Enable an External Port
Partitioning the InfiniBand Fabric
smpartition
Command
smpartition
Command Guidelines
Partitions and P_Keys
Determine the Partitions and P_Keys
Create a User Partition
Add or Remove a Port From a Partition
Modify a Partition or Port
Delete a Partition
Remove User Partitions for Firmware Downgrade
Correlating Fabric Elements
createfabric
Command
Create a Fabric Element Configuration
Add or Delete an Element From the Configuration
Modify an Element of the Configuration
Configuring the Fabric Director Node List
Fabric Director and Fabric Elements
fdconfig
Command Overview
Create a Fabric Configuration
Add or Remove an Element From the Fabric Configuration
Modify an Element of the Fabric Configuration
Performing Supportive Tasks
Create the
smnodes
List
Update the
smnodes
List
Create the IPoIB Interface
Delete the IPoIB Interface
Administering Gateway Resources
Installing Gateway Supportive Software (Linux)
Acquire the BXOFED Software (Linux)
Install the BXOFED Software (Linux)
Acquire the ConnectX-2 Firmware
Creating VNICs Under Gateway Manual Mode (Linux)
Gateway Manual Mode Overview (Linux)
Determine VNIC Configuration Parameters For Gateway Manual Mode (Linux)
Determine VLAN Associations for Gateway Manual Mode (Linux)
Configure and Create VNICs for Gateway Manual Mode (Linux)
VNIC Configuration on Linux Hosts in Gateway Manual Mode
Creating VNICs Under Host Manual Mode (Linux)
Host Manual Mode Overview (Linux)
Central Configuration File (Linux)
VNIC-Specific Configuration File (Linux)
Determine VNIC Configuration Parameters for Host Manual Mode (Linux)
Create the Central Configuration File (Linux)
Create the VNIC-Specific Configuration Files (Linux)
mlx4_vnic_confd
Daemon (Linux)
Configure and Create VNICs for Host Manual Mode (Linux)
Creating Virtual IO Adapters (Oracle Solaris)
Ethernet Over InfiniBand Overview (Oracle Solaris)
Verify That the Ethernet Over InfiniBand Driver Is Installed (Oracle Solaris)
Install the Ethernet Over InfiniBand Driver (Oracle Solaris)
Set Up VIOAs (Oracle Solaris)
Configure IP Addresses on the Data Link (Oracle Solaris)
Create Oracle Solaris VNICs With VLAN Tagging (Oracle Solaris)
Monitoring Gateway Resources
Display LAG Information
Display the VLANs
Display the VNICs
Display IO Adapters
Display Gateway Ethernet Port Information
Display Gateway Port Information
Display the Gateway Instance Number
Display Information About the Gateway
Controlling LAGs
Enable LAG Mode
Create LAGs
Create a Global Gateway
Add or Delete Connectors From a LAG
Delete a LAG
Disable LAG Mode
Controlling VLANs and VNICs
VNIC Allocation on the Gateway
Create VLANs
Delete VLANs
Create VNICs
Modify VNICs
Enable VNICs
Disable VNICs
Delete VNICs
Controlling Gateway Ports and Parameters
Enable a Gateway Ethernet Port
Disable a Gateway Ethernet Port
Set the Gateway Ethernet Port Parameters
Set the Gateway Service Level
Set the Gateway Instance Number
Set the Gateway System Name
Remote Management
Understanding Oracle ILOM on the Gateway
Oracle ILOM Overview
Supported Features
Understanding Oracle ILOM Targets
Oracle ILOM Target Overview
Oracle ILOM Targets and Descriptions
Oracle ILOM General System Targets and Properties
Oracle ILOM Fan Targets and Properties
Oracle ILOM Indicator Targets and Properties
Oracle ILOM Power Supply Targets and Properties
Oracle ILOM Temperature Targets and Properties
Oracle ILOM Voltage Targets and Properties
Oracle ILOM Voltage State Targets and Properties
Oracle ILOM General Targets and Properties
Oracle ILOM Service Targets and Properties
Oracle ILOM User and Session Targets and Properties
Administering Oracle ILOM (CLI)
CLI Overview
Accessing Oracle ILOM From the CLI
Access the Oracle ILOM Shell From the CLI (NET MGT Port)
Access the Oracle ILOM Shell From the CLI (USB Management Port)
Switching Between the Oracle ILOM Shell and the Linux Shell
/SYS/Switch_Diag
,
/SYS/Gateway_Mgmt
, and
/SYS/Fabric_Mgmt
Linux Shells
Switch From the Oracle ILOM Shell to the Linux Shell
Switch From the Linux Shell to the Oracle ILOM Shell
Monitoring Oracle ILOM Targets (CLI)
Performing Daily Tasks (CLI)
Display the Date (CLI)
Display Faulted System Components (CLI)
Display Gateway Status LEDs States (CLI)
Display the Aggregate Sensors State (CLI)
Aggregate Sensor States
Display Power Supply Status (CLI)
Display Board-Level Voltages (CLI)
Board Level Voltages
Display Internal Temperatures (CLI)
Internal Temperature Sensors
Display Fan Status (CLI)
Display the Oracle ILOM Sessions (CLI)
Display the Oracle ILOM Event Log (CLI)
Oracle ILOM Log Entry Filters
Checking the Status of Services (CLI)
Display the HTTP Service Status (CLI)
Display the HTTPS Service Status (CLI)
Display the SSL Certificates (CLI)
Display the SNMP Service Status (CLI)
Display the SNMP User Accounts (CLI)
Display the SNMP Service Communities (CLI)
Display the IPMI Service Status (CLI)
Display the DNS Client Status (CLI)
Display the SMTP Client Status (CLI)
Display the NTP Servers (CLI)
Verifying Other Aspects With Oracle ILOM (CLI)
Get Help on an Oracle ILOM Command (CLI)
Get Help on an Oracle ILOM Target Property (CLI)
Display the Alert Properties (CLI)
Display the Oracle ILOM User Accounts (CLI)
Display the Remote Log Hosts (CLI)
Display the Network Management Configuration (CLI)
Display the CLI Session Timeout (CLI)
Display Gateway FRU ID (CLI)
Display Power Supply FRU ID (CLI)
Display the Firmware Version (CLI)
Display System Identification Properties (CLI)
Controlling Oracle ILOM Targets (CLI)
Performing General Tasks on Oracle ILOM Targets (CLI)
Restart the Management Controller (CLI)
Set the Date and Time (CLI)
Clear Faulted System Components (CLI)
Enable the Locator LED (CLI)
Disable the Locator LED (CLI)
Clear the Oracle ILOM Event Log (CLI)
Set the Remote Log Hosts (CLI)
Configure the DNS Client (CLI)
Configure the SMTP Client (CLI)
Back Up the Configuration (CLI)
Gateway Configuration Information Backed Up
Restore the Configuration (CLI)
Create a Snapshot of the Gateway State (CLI)
Snapshot Dataset Information (CLI)
Set the Network Management Parameters (CLI)
Set the System Identification Properties (CLI)
Performing Oracle ILOM User Tasks (CLI)
Add an Oracle ILOM User Account (CLI)
Change an Oracle ILOM User's Password and or Role (CLI)
Delete an Oracle ILOM User Account (CLI)
Managing HTTP Services (CLI)
Enable the HTTP Service (CLI)
Disable the HTTP Service (CLI)
Managing HTTPS Services (CLI)
Enable the HTTPS Service (CLI)
Install a Custom SSL Certificate and Key (CLI)
Remove the Custom SSL Certificate and Key (CLI)
Disable the HTTPS Service (CLI)
Managing SNMP Services (CLI)
Enable the SNMP Service (CLI)
Configure the SNMP Service (CLI)
Add SNMP Service User Accounts (CLI)
Modify SNMP Service User Accounts (CLI)
Delete SNMP Service User Accounts (CLI)
Add SNMP Service Communities (CLI)
Modify SNMP Service Communities (CLI)
Delete SNMP Service Communities (CLI)
Download SNMP Service MIBs (CLI)
Disable the SNMP Service (CLI)
Managing IPMI Services (CLI)
Enable the IPMI Service (CLI)
Disable the IPMI Service (CLI)
Managing Other Aspects With Oracle ILOM (CLI)
Enable Alerts to Send SNMP Traps (CLI)
Enable Alerts to Send PETs (CLI)
Enable Alerts to Send Email Alerts (CLI)
Disable Alerts (CLI)
Set the Oracle ILOM CLI Session Timeout (CLI)
Upgrading the Gateway Firmware Through Oracle ILOM (CLI)
Firmware Overview
Verify Firmware Integrity (CLI)
Acquire the Gateway Firmware Package (CLI)
Upgrade the Gateway Firmware (CLI)
Administering Oracle ILOM (Web)
Web Interface Overview
Access Oracle ILOM From the Web Interface
Monitoring Oracle ILOM Targets (Web)
Performing Daily Tasks (Web)
Display the Date (Web)
Display Faulted System Components (Web)
Display the Gateway Status LEDs States (Web)
Display the Aggregate Sensors State (Web)
Display Power Supply Status (Web)
Display Board-Level Voltages (Web)
Display Internal Temperatures (Web)
Display Fan Status (Web)
Display the Oracle ILOM Sessions (Web)
Display the Oracle ILOM Event Log (Web)
Checking the Status of Services (Web)
Display the HTTP Service Status (Web)
Display the HTTPS Service Status (Web)
Display the SSL Certificates (Web)
Display the SNMP Service Status (Web)
Display the SNMP Service User Accounts (Web)
Display the SNMP Service Communities (Web)
Display the IPMI Service Status (Web)
Display the DNS Client Status (Web)
Display the SMTP Client Status (Web)
Display the Network Time Protocol Servers (Web)
Verifying Other Aspects With Oracle ILOM (Web)
Display the Alert Properties (Web)
Display the Oracle ILOM User Accounts (Web)
Display the Remote Log Hosts (Web)
Display the Network Management Configuration (Web)
Display the CLI Session Timeout (Web)
Display System Component FRU ID (Web)
Display the Firmware Version (Web)
Display the Oracle ILOM Version (Web)
Display System Identification Properties (Web)
Controlling Oracle ILOM Targets (Web)
Performing General Tasks on Oracle ILOM Targets (Web)
Restart the Management Controller (Web)
Set the Date and Time (Web)
Set the Time Zone (Web)
Clear Faulted System Components (Web)
Enable the Locator LED (Web)
Disable the Locator LED (Web)
Clear the Oracle ILOM Event Log (Web)
Set the Remote Log Hosts (Web)
Configure the DNS Client (Web)
Configure the SMTP Client (Web)
Back Up the Configuration (Web)
Restore the Configuration (Web)
Create a Snapshot of the Gateway State (Web)
Snapshot Dataset Information (Web)
Set the Network Management Parameters (Web)
Set the System Identification Properties (Web)
Performing Oracle ILOM User Tasks (Web)
Add an Oracle ILOM User Account (Web)
Change an Oracle ILOM User's Password and or Role (Web)
Delete an Oracle ILOM User Account (Web)
Managing HTTP Services (Web)
Enable the HTTP Service (Web)
Disable the HTTP Service (Web)
Managing HTTPS Services (Web)
Enable the HTTPS Service (Web)
Install a Custom SSL Certificate and Key (Web)
Remove the Custom SSL Certificate and Key (Web)
Disable the HTTPS Service (Web)
Managing SNMP Services (Web)
Enable the SNMP Service (Web)
Configure the SNMP Service (Web)
Add SNMP Service User Accounts (Web)
Modify SNMP Service User Accounts (Web)
Delete SNMP Service User Accounts (Web)
Add SNMP Service Communities (Web)
Modify SNMP Service Communities (Web)
Delete SNMP Service Communities (Web)
Download SNMP Service MIBs (Web)
Disable the SNMP Service (Web)
Managing IPMI Services (Web)
Enable the IPMI Service (Web)
Disable the IPMI Service (Web)
Managing Other Aspects With Oracle ILOM (Web)
Enable Alerts to Send SNMP Traps (Web)
Enable Alerts to Send PETs (Web)
Enable Alerts to Send Email Alerts (Web)
Disable Alerts (Web)
Set the CLI Session Timeout (Web)
Upgrade the Gateway Firmware (Web)
Using the Fabric Monitor
Access the Fabric Monitor
Fabric Monitor Features
Accessing the Rear Panel Diagram
Rear Panel Diagram Overview
InfiniBand Connector Status Window
Gateway Connector Status Window
BridgeX Port Status Window
Accessing Status Pane Information
System Info Tab
Sensor Info Tab
IB Performance Tab
IB Port Map Tab
Subnet Manager Tab
Control Panel Function
Monitoring Parameters and Status
Chassis Parameters and Status
InfiniBand Connector Parameters and Status
Gateway Connector Parameters and Status
I4 to Gateway Interface Parameters and Status
I4 Switch Chip Port Parameters and Status
Administering Oracle ILOM (SNMP)
SNMP Overview
Understanding SNMP Commands
SNMP Commands
V1 and V2c Protocol Command Format
V3 Protocol Command Format
Monitoring Oracle ILOM Targets (SNMP)
Performing Daily Tasks (SNMP)
Display the Date and Time (SNMP)
Display the Time Zone (SNMP)
Display the Aggregate Sensors State (SNMP)
Display Power Supply Status (SNMP)
Display Board-Level Voltages (SNMP)
Display Internal Temperatures (SNMP)
Display Fan Status (SNMP)
Display the Sensor Alarm State (SNMP)
Display the Entity Numbers
Display Oracle ILOM Sessions (SNMP)
Display the Oracle ILOM Event Log (SNMP)
Checking the Status of Services (SNMP)
Display the HTTP Service Status (SNMP)
Display the HTTPS Service Status (SNMP)
Display the DNS Client Status (SNMP)
Display the SMTP Client Status (SNMP)
Display the NTP State (SNMP)
Display the NTP Servers (SNMP)
Verifying Other Aspects With Oracle ILOM (SNMP)
Display the Alert Properties (SNMP)
Display Oracle ILOM User Accounts (SNMP)
Display the Remote Log Hosts (SNMP)
Display the Network Management Configuration (SNMP)
Display Gateway FRU ID (SNMP)
Display Power Supply FRU ID (SNMP)
Display the System Components (SNMP)
Display the Additional System Component Information (SNMP)
Display the Firmware Version (SNMP)
Display System Identification Properties (SNMP)
Controlling Oracle ILOM Targets (SNMP)
Performing General Tasks (SNMP)
Set the Date and Time (SNMP)
Set the Time Zone (SNMP)
Set the Network Time Protocol State (SNMP)
Set the Network Time Protocol Servers (SNMP)
Clear the Oracle ILOM Event Log (SNMP)
Set the Remote Log Hosts (SNMP)
Configure the DNS Client (SNMP)
Configure the SMTP Client (SNMP)
Set the Network Parameters (SNMP)
Set the System Identification Properties (SNMP)
Performing User Tasks (SNMP)
Add an Oracle ILOM User Account (SNMP)
Delete an Oracle ILOM User Account (SNMP)
Managing Other Aspects With Oracle ILOM (SNMP)
Set the HTTP Service State (SNMP)
Set the HTTPS Service State (SNMP)
Enable Alerts to Send SNMP Traps (SNMP)
Enable Alerts to Send PETs (SNMP)
Enable Alerts to Send Email Alerts (SNMP)
Modify Alert SNMP Version (SNMP)
Disable Alerts (SNMP)
Administering Hardware (IPMI)
ipmitool
Overview
Display the Sensor States (IPMI)
Display the Sensor Information (IPMI)
Display the System Event Log (IPMI)
Display FRU ID Information (IPMI)
Display Gateway Status LED States (IPMI)
Enable the Locator LED (IPMI)
Disable the Locator LED (IPMI)
Understanding Oracle ILOM Commands
cd
Command
create
Command
delete
Command
dump
Command
exit
Command (Oracle ILOM)
help
Command (Oracle ILOM)
load
Command
reset
Command
set
Command
show
Command
version
Command (Oracle ILOM)
Service
Detecting and Managing Faults
Interpreting Status LEDs
Front Panel LEDs
Rear Panel LEDs
Check Chassis Status LEDs
Check NET MGT Port Status LEDs
Check Link Status LEDs
Check Power Supply Status LEDs
Check Fan Status LEDs
Managing Faulty Components
Display Faulty Components (
fault_state
)
Display Faulty Components (
/SP/faultmgmt
)
Clear a Fault Manually
Clearable Fault Targets
Identify Faults in the Oracle ILOM Event Log
Determining the Alarm State of a Component or System
Display the General Alarm State of Systems and Components
System Alarm Targets
Component Alarm Targets
Oracle ILOM Target Alarm States
Evaluating Sensor Alarms
Display Oracle ILOM Sensor Status
Determine Oracle ILOM Sensor Target Types
Evaluating a Voltage Sensor Alarm
Evaluate a Voltage Sensor
Voltage Sensor Values
Voltage Out of Range
Evaluating a Temperature Sensor Alarm
Evaluate a Temperature Sensor
Temperature Sensor Values
Temperature Out of Range
Evaluating a Speed Sensor Alarm
Evaluate a Speed Sensor
Speed Sensor Values
Speed Out of Range
Evaluating a State Sensor Alarm
Evaluate a State Sensor
State Sensor Alarm Conditions
Evaluating a Presence Sensor Alarm
Evaluate a Presence Sensor
Presence Sensor Alarm Conditions
Evaluating an Indicator State
Evaluate an Indicator State
Indicator State Values
Indicator State Conditions
Accessing CLI Prompts
Access the Oracle ILOM CLI (NET MGT Port)
Enter the Restricted Linux Shell
Exit the Restricted Linux Shell
Understanding Service Procedures
Replaceable Components
Suggested Tools for Service
Antistatic Precautions for Service
Servicing Power Supplies
Determine If a Power Supply Is Faulty
Inspecting a Power Supply
Identify the Power Supply
Inspect the Power Supply Hardware
Inspect the Power Supply Connectors
Power Off a Power Supply
Remove a Power Supply
Install a Power Supply
Power On a Power Supply
Servicing Fans
Determine If a Fan Is Faulty
Inspecting a Fan
Identify the Fan
Inspect the Fan Hardware
Inspect the Fan Connector
Remove a Fan
Install a Fan
Servicing Data Cables
Inspecting the Data Cables
Identify the Data Cable
Inspect the Data Cable Hardware
Inspect the Data Cable Connectors or Transceivers
Remove a Data Cable
Install a Data Cable
Servicing the Battery
Determine If the Battery Is Faulty
Remove the Gateway From the Rack
Replace the Battery
Reference
Understanding Hardware Commands
Linux Shells for Hardware Commands
addlagport
Command
allowhostconfig
Command
autodisable
Command
checkboot
Command
checkpower
Command
checktopomax
Command
checkvoltages
Command
connector
Command
create_ipoib
Command
createfabric
Command
createlag
Command
createvlan
Command
createvnic
Command
dcsport
Command
delete_ipoib
Command
deletelag
Command
deletevlan
Command
deletevnic
Command
dellagport
Command
disablecablelog
Command
disablegwport
Command
disablelagmode
Command
disablelinklog
Command
disablesm
Command
disableswitchport
Command
disablevnic
Command
disallowhostconfig
Command
enablecablelog
Command
enablegwport
Command
enablelagmode
Command
enablelinklog
Command
enablesm
Command
enableswitchport
Command
enablevnic
Command
env_test
Command
exit
Command (Hardware)
fdconfig
Command
fwverify
Command
generatetopology
Command
getfanspeed
Command
getmaster
Command
getportcounters
Command
getportstatus
Command
help
Command (Hardware)
listlinkup
Command
localmkeypersistence
Command
matchtopology
Command
modifyvnic
Command
setcontrolledhandover
Command
setdefaultgwdiscpkey
Command
setgwethport
Command
setgwinstance
Command
setgwsl
Command
setgwsystemname
Command
sethostvniclimit
Command
setmsmlocationmonitor
Command
setsmmkey
Command
setsmpriority
Command
setsmrouting
Command
setsubnetprefix
Command
showdisk
Command
showfree
Command
showfruinfo
Command
showgwconfig
Command
showgwports
Command
showioadapters
Command
showlag
Command
showpsufru
Command
showsmlog
Command
showtemps
Command
showtopology
Command
showunhealthy
Command
showvlan
Command
showvnics
Command
smconfigtest
Command
smnodes
Command
smpartition
Command
smsubnetprotection
Command
version
Command (Hardware)
Understanding InfiniBand Commands
Linux Shells for InfiniBand Commands
ibdiagnet
Command
ibhosts
Command
ibnetdiscover
Command
ibnetstatus
Command
ibnodes
Command
ibportstate
Command
ibroute
Command
ibrouters
Command
ibstat
Command
ibswitches
Command
ibtracert
Command
perfquery
Command
saquery
Command
smpquery
Command
Understanding SNMP MIB OIDs
OID Tables Overview
Understanding the
SUN-DCS-IB-MIB
MIB OIDs
SUN-DCS-IB-MIB
MIB OID Command Syntax
Enclosure OIDs
Enclosure Nodes OIDs
Neighbor Node OIDs
Subnet Manager Info OIDs
Subnet Manager Agent Data Port OIDs
Understanding Performance Manager Agent OIDs
PMA Port Counters Table OIDs
PMA Extended Port Counters Table OIDs
Understanding SNMP Trap OIDs
Trap Control OIDs
Trap Threshold OIDs
Trap Notification OIDs
IB Trap OIDs
Understanding Gateway Specific OIDs
Gateway Port Status OIDS
Gateway Port Counter OIDS
Understanding the
SUN-FABRIC-MIB
MIB OIDs
SUN-FABRIC-MIB
MIB OID Command Syntax
Fabric Element OIDs
Fabric Management OIDs
Fabric Management Element OIDs
Fabric Management External Element OIDs
Fabric Management Gateway OIDs
Fabric Management Link OIDs
Fabric Trap Configuration OIDs
Understanding the
SUN-HW-TRAP-MIB
MIB OIDs
Hardware Trap Configuration OIDs
Hardware Traps
Hardware Fault Traps
Understanding the
SUN-ILOM-CONTROL-MIB
MIB OIDs
SUN-ILOM-CONTROL-MIB
MIB OID Command Syntax
NTP OIDs
Remote Syslog OIDs
HTTP OIDs
HTTPS OIDs
Network OIDs
User OIDs
Session OIDs
Event Log OIDs
Alert OIDs
Clock OIDs
Backup and Restore OIDs
Identification OIDs
SMTP OIDs
DNS OIDs
Understanding the
SUN-PLATFORM-MIB
MIB OIDs
SUN-PLATFORM-MIB
MIB OID Command Syntax
Understanding MIB Physical OIDs
High-Level OIDs
NIM Equipment Table OIDs
Physical Class Extension Table OIDs
Sun Platform Sensor Table OIDs
Sun Platform Numeric Sensor Table OIDs
Discrete Sensor Table OIDs
Sun Platform Fan Table OIDs
Sun Platform Alarm Table OIDs
Understanding the
ENTITY-MIB
MIB OIDs
ENTITY-MIB
MIB OID Command Syntax
Physical Entity Table OIDs
Index
A
B
C
D
E
F
G
H
I
L
M
N
O
P
Q
R
S
T
U
V
W