Oracle EDR InfiniBand Switch and Virtualized I/O Systems Administration Guide

Exit Print View

Updated: November 2016
 
 

Display the MBOM Power Information (Oracle ILOM CLI)

The switch contains MBOM units that enable the EDR connections to EDR-capable hosts. Valid operating power values for the MBOMs are programmed at the factory, so you can read the voltages and event thresholds, but not set them.

  • Display the 3.3-volt power conditions for the power supplied to all MBOMs.
    -> show -d properties /SYS/MB/V_+3V3_MBOMA
    /SYS/MB/V_+3V3_MBOMA
    	Properties:
    		type = Voltage
    		ipmi_name = MB/V_+3V3_MBOMA
    		class = Threshold Sensor
    		value = 3.256 Volts
    		upper_nonrecov_threshold = 3.510 Volts
    		upper_critical_threshold = 3.490 Volts
    		upper_noncritical_threshold = 3.471 Volts
    		lower_noncritical_threshold = 3.139 Volts
    		lower_critical_threshold = 3.120 Volts
    		lower_nonrecov_threshold = 3.101 Volts
    		alarm_status = cleared
    
    ->
    

Related Information