Oracle EDR InfiniBand Switch and Virtualized I/O Systems Administration Guide

Exit Print View

Updated: November 2016
 
 

/SYS Power Supply Chassis Targets and Properties

Use the show command on the /SYS/PSx targets to display information about and status for the power supplies. Use the set command to configure the clear_fault_action property to manually clear a power supply fault.


Note -  Properties indicated as Not Supported or N/A are not listed.
Oracle ILOM Target
Properties
Description
/SYS/PSx
  • type = Power Supply

  • ipmi_name = PSx

  • fru_manufacturer = Delta Electronics

  • fru_part_number = 7065505-01

  • fru_serial_number = C94928

  • fault_state = OK

  • clear_fault_action = (none)

Power supply x information.
/SYS/PSx/INPUT_POWER
  • type = Power Unit

  • ipmi_name = PSx/IN_POWER

  • class = Threshold Sensor

  • value = 209.916 Watts

  • alarm_status = cleared

Power supply x input power information.
/SYS/PSx/I_IN
  • type = Current

  • ipmi_name = PSx/I_IN

  • class = Threshold Sensor

  • value = 1.827 Amps

  • alarm_status = cleared

Power supply x input current information.
/SYS/PSx/I_OUT
  • type = Current

  • ipmi_name = PSx/I_OUT

  • class = Threshold Sensor

  • value = 16.00 Amps

  • alarm_status = cleared

Power supply x output current information.
/SYS/PSx/OUTPUT_POWER
  • type = Power Unit

  • ipmi_name = PSx/OUT_POWER

  • class = Threshold Sensor

  • value = 180.000 Watts

  • alarm_status = cleared

Power supply x output power information.
/SYS/PSx/PRSNT
  • type = Entity Presence

  • ipmi_name = PSx/PRSNT

  • class = Discrete Sensor

  • value = Present

  • alarm status = cleared

Presence and alarm status of power supply x.
/SYS/PSx/PWROK
  • type = Power Supply

  • ipmi_name = PSx/PRSNT

  • class = Discrete Sensor

  • value = State Asserted

  • alarm status = cleared

Power supply x power state.
/SYS/PSx/V_IN
  • type = Voltage

  • ipmi_name = PSx/V_IN

  • class = Threshold Sensor

  • value = 119.000 Volts

  • upper_nonrecov_threshold = 255.000 Volts

  • upper_critical_threshold = 252.000 Volts

  • lower_critical_threshold = 100.000 Volts

  • lower_nonrecov_threshold = 90.000 Volts

  • alarm_status = cleared

Power supply xinput voltage information.
/SYS/PSx/V_OUT
  • type = Voltage

  • ipmi_name = PSx/V_OUT

  • class = Threshold Sensor

  • value = 12.000 Volts

  • upper_nonrecov_threshold = 20.000 Volts

  • upper_critical_threshold = 14.000 Volts

  • lower_critical_threshold = 10.000 Volts

  • alarm_status = cleared

Power supply xoutput voltage information.
/SYS/PS_3V3
  • type = Voltage

  • class = Threshold Sensor

  • value = 3.412 Volts

  • upper_nonrecov_threshold = 3.783 Volts

  • upper_critical_threshold = 3.685 Volts

  • upper_noncritical_threshold = 3.471 Volts

  • lower_noncritical_threshold = 3.120 Volts

  • lower_critical_threshold = 2.944 Volts

  • lower_nonrecov_threshold = 2.789 Volts

  • alarm_status = cleared

3.3 Volt power information.