/SYS Power Supply Chassis Targets and Properties
Use the show command on the
/SYS/PSx targets to display
information about and status for the power supplies. Use the set
command to configure the clear_fault_action property to
manually clear a power supply fault.
Note -
Properties indicated as Not Supported or
N/A are not listed.
|
|
|
/SYS/PSx
|
-
type = Power Supply
-
ipmi_name = PSx
-
fru_manufacturer = Delta
Electronics
-
fru_part_number =
7065505-01
-
fru_serial_number =
C94928
-
fault_state = OK
-
clear_fault_action =
(none)
|
Power supply x information.
|
/SYS/PSx/INPUT_POWER
|
-
type = Power Unit
-
ipmi_name =
PSx/IN_POWER
-
class = Threshold
Sensor
-
value = 209.916 Watts
-
alarm_status = cleared
|
Power supply x input power
information.
|
/SYS/PSx/I_IN
|
-
type = Current
-
ipmi_name =
PSx/I_IN
-
class = Threshold
Sensor
-
value = 1.827 Amps
-
alarm_status = cleared
|
Power supply x input current
information.
|
/SYS/PSx/I_OUT
|
-
type = Current
-
ipmi_name =
PSx/I_OUT
-
class = Threshold
Sensor
-
value = 16.00 Amps
-
alarm_status = cleared
|
Power supply x output current
information.
|
/SYS/PSx/OUTPUT_POWER
|
|
Power supply x output power
information.
|
/SYS/PSx/PRSNT
|
-
type = Entity Presence
-
ipmi_name =
PSx/PRSNT
-
class = Discrete
Sensor
-
value = Present
-
alarm status = cleared
|
Presence and alarm status of power supply
x.
|
/SYS/PSx/PWROK
|
-
type = Power Supply
-
ipmi_name =
PSx/PRSNT
-
class = Discrete
Sensor
-
value = State Asserted
-
alarm status = cleared
|
Power supply x power state.
|
/SYS/PSx/V_IN
|
-
type = Voltage
-
ipmi_name =
PSx/V_IN
-
class = Threshold
Sensor
-
value = 119.000 Volts
-
upper_nonrecov_threshold = 255.000
Volts
-
upper_critical_threshold = 252.000
Volts
-
lower_critical_threshold = 100.000
Volts
-
lower_nonrecov_threshold = 90.000
Volts
-
alarm_status = cleared
|
Power supply xinput voltage information.
|
/SYS/PSx/V_OUT
|
-
type = Voltage
-
ipmi_name =
PSx/V_OUT
-
class = Threshold
Sensor
-
value = 12.000 Volts
-
upper_nonrecov_threshold = 20.000
Volts
-
upper_critical_threshold = 14.000
Volts
-
lower_critical_threshold = 10.000
Volts
-
alarm_status = cleared
|
Power supply xoutput voltage information.
|
/SYS/PS_3V3
|
-
type = Voltage
-
class = Threshold
Sensor
-
value = 3.412 Volts
-
upper_nonrecov_threshold = 3.783
Volts
-
upper_critical_threshold = 3.685
Volts
-
upper_noncritical_threshold = 3.471
Volts
-
lower_noncritical_threshold = 3.120
Volts
-
lower_critical_threshold = 2.944
Volts
-
lower_nonrecov_threshold =
2.789 Volts
-
alarm_status = cleared
|
3.3 Volt power information.
|
|