Oracle EDR InfiniBand Switch and Virtualized I/O Systems Administration Guide

Exit Print View

Updated: November 2016
 
 

/System Systemic Targets and Properties

Use the show command on the /System targets to display information and general health of the systems within the chassis. Use the set command to configure the action, clear, and load_uri property to reset switches, clear logs, and load firmware respectively.


Note -  Properties indicated as Not Supported or N/A are not listed.
Oracle ILOM Target
Properties
Description
/System
  • health = OK

  • health_details = -

  • open_problems_count = 0

  • type = Rack Mount

  • model = Unknown

  • part_number= Unknown

  • serial_number = Unknown

  • system_identifier = (none)

  • system_fw_version = 3.2.0.0

  • ilom_address = 0.0.0.0

  • ilom_mac_address = 00:00:AB:1C:D2:34

  • locator_indicator = Off

  • power_state = On

  • actual_power_consumption = Unknown

  • action = (none)

System configuration and common equipment information.
/System/Open_Problems
No properties.
Problematic components.
/System/Power
  • health = OK

  • health_details = -

  • actual_power_consumption = Unknown

  • max_permitted_power = Unknown

  • installed_power_supplies = 2

  • max_power_supplies = 2

Power system information.
/System/Power/Power_Supplies/Power_Supply_x
  • health = OK

  • health_details = -

  • part_number = 7065505-01

  • serial_number = C94928

  • manufacturer = Delta Electronics

  • location = PSO (Power Supply 0)

Power supply information.
/System/Cooling
  • health = OK

  • health_details = -

  • installed_chassis_fans = 8

  • max_chassis_fans = 8

  • inlet_temp = 32 degrees C

  • exhaust_temp = 36 degrees C

Cooling system information.
/System/Cooling/Fans/Fan_x
  • health = OK

  • health_details = -

  • part_number = Unknown

  • serial_number = Unknown

  • location = FMO (Fan Module 0)

  • fan_percentage = 30%

Fan information.
/System/Networking
  • health = Unknown

  • health_details = -

  • installed_eth_nics = 0

  • installed_ethernet_switches = 1

  • max_ethernet_switches = 1

  • installed_infiniband_switches = 1

  • max_infiniband_switches = 1

Ethernet switch and switch-chip information.
/System/Networking/Modules/Module_X
  • health = OK

  • health_details = -

  • type = InfiniBand

  • location = MODULEX (Network Module 0)

  • action = (none)

Oracle F2 I/O modules for virtualization switch.
Oracle F2 I/O modules have various sensors. See Oracle ILOM Module Targets Overview.
/System/Networking/Switches/Switch_0
  • health = Unknown

  • health_details = -

  • type = Ethernet

  • firmware_version = Unknown

  • location = ETHSWITCH0 (Network Switch 0)

  • action = (none)

  • load_uri = (none)

Ethernet switch information.
/System/Networking/Switches/0/fs_cli
  • action = (none)

Ethernet switch CLI interface control.
/System/Networking/Switches/0/sefos
  • action = (none)

Ethernet switch SEFOS interface control.
/System/Networking/Switches/Switch_1
  • health = OK

  • health_details = -

  • type = Infiniband

  • firmware_version = 1.0.0 BUILD-20150827-686

  • location = IBSWITCH0 (Network Switch 0)

  • action = (none)

IB switch information.
/System/Firmware
  • system_fw_version = 3.2.0.0

System firmware information.
/System/Firmware/Other_Firmware/Firmware_0
  • component = ILOM

  • type = ILOM Firmware

  • version = 3.2.0.0

Oracle ILOM firmware information.
/System/Firmware/Other_Firmware/Firmware_1
  • component = BIOS

  • type = System BIOS

  • version = Unknown

BIOS firmware information.
/System/Firmware/Other_Firmware/Firmware_2
  • component = SYS ETHSWITCH0

  • type = Upgradeable FRU

  • version = Not Available

  • load_uri = (none)

System Ethernet switch firmware information.
/System/Log
  • clear = (none)

System log management.
/System/Log/list
No properties.
System log itself.

Related Information