The switch has internal HCAs for EDR connectivity. You can display the power consumption for each type of power the HCA uses as well as event thresholds for power supplied to the HCAs.
-> show /SYS/MB/V_+0V85_HCA
Properties:
type = Voltage
ipmi_name = MB/V_+0V85_HCA
class = Threshold Sensor
value = 0.847 Volts
upper_nonrecov_threshold = 0.941 Volts
upper_critical_threshold = 0.931 Volts
upper_noncritical_threshold = 0.921 Volts
lower_noncritical_threshold = 0.833 Volts
lower_critical_threshold = 0.823 Volts
lower_nonrecov_threshold = 0.813 Volts
alarm_status = cleared
->
-> show /SYS/MB/V_+1V05_HCA
/SYS/MB/V_+1V05_
Properties:
type = Voltage
ipmi_name = MB/V_+1V05_HCA
class = Threshold Sensor
value = 1.091 Volts
upper_nonrecov_threshold = 1.137 Volts
upper_critical_threshold = 1.127 Volts
upper_noncritical_threshold = 1.117 Volts
lower_noncritical_threshold = 1.019 Volts
lower_critical_threshold = 1.000 Volts
lower_nonrecov_threshold = 0.980 Volts
alarm_status = cleared
->