Environmental Event Traps
Description – A temperature sensor has
reported that its value has gone above an upper fatal threshold setting or below a
lower fatal threshold setting. The sunHwTrapThresholdType object
indicates whether the threshold was an upper or lower.
|
|
|
|
sunHwTrapTempFatalThresholdExceeded
|
Lower fatal threshold exceeded
|
Critical
|
/SYS/PS0/T_OUT
/SYS/PS1/T_OUT
/SYS/MB/T_IN_ZONE0
/SYS/MB/T_OUT_ZONE0
/SYS/MB/T_IN_ZONE1
/SYS/MB/T_OUT_ZONE1
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
|
sunHwTrapTempFatalThresholdDeasserted
|
Lower fatal threshold no longer exceeded
|
Informational
|
/SYS/PS0/T_OUT
/SYS/PS1/T_OUT
/SYS/MB/T_IN_ZONE0
/SYS/MB/T_OUT_ZONE0
/SYS/MB/T_IN_ZONE1
/SYS/MB/T_OUT_ZONE1
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
|
sunHwTrapTempCritThresholdExceeded
|
Upper critical threshold exceeded
|
Critical
|
/SYS/PS0/T_OUT
/SYS/PS1/T_OUT
/SYS/MB/T_IN_ZONE0
/SYS/MB/T_OUT_ZONE0
/SYS/MB/T_IN_ZONE1
/SYS/MB/T_OUT_ZONE1
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
|
sunHwTrapTempCritThresholdDeasserted
|
Upper critical threshold no longer exceeded
|
Informational
|
/SYS/PS0/T_OUT
/SYS/PS1/T_OUT
/SYS/MB/T_IN_ZONE0
//SYS/MB/T_OUT_ZONE0
/SYS/MB/T_IN_ZONE1
/SYS/MB/T_OUT_ZONE1
/SYS/MB/T_IN_ZONE2
/SYS/MB/T_OUT_ZONE2
|
sunHwTrapTempFatalThresholdExceeded
|
Lower fatal threshold exceeded
|
Critical
|
/SYS/T_AMB
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
|
sunHwTrapTempFatalThresholdDeasserted
|
Lower fatal threshold no longer exceeded
|
Informational
|
/SYS/T_AMB
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
|
sunHwTrapTempCritThresholdExceeded
|
Upper critical threshold exceeded
|
Critical
|
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
|
sunHwTrapTempCritThresholdDeasserted
|
Upper critical threshold no longer exceeded
|
Informational
|
/SYS/MB/T_CORE_NET01
/SYS/MB/T_CORE_NET23
/SYS/MB/T_IN_PS
|
|