Power Event Traps

Description – A power supply sensor has detected an error.

SNMP Trap Message
Oracle ILOM Event Message
Severity
Sensor Name
sunHwTrapPowerSupplyError
Presence Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Presence Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Failure Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Failure Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Predictive Failure Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Predictive Failure Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Input Lost Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Input Lost Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Input Error Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Input Error Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Input Range Error Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Input Range Error Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Config Error Assert
Major
/SYS/PS[0-1]/STATE
sunHwTrapPowerSupplyError
Config Error Deassert
Major
/SYS/PS[0-1]/STATE
sunHwTrapSensorNonCritThresholdExceeded
Upper noncritical threshold exceeded
Minor
/SYS/VPS
sunHwTrapSensorThresholdOk
Upper noncritical threshold no longer exceeded
Informational
/SYS/VPS
sunHwTrapSensorNonCritThresholdExceeded
Upper noncritical threshold exceeded
Minor
/SYS/VPS_FANS
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
sunHwTrapSensorThresholdOk
Upper noncritical threshold no longer exceeded
Informational
/SYS/VPS_FANS
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
sunHwTrapSensorFatalThresholdExceeded
Lower fatal threshold exceeded
Critical
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
sunHwTrapSensorFatalThresholdDeasserted
Lower fatal threshold no longer exceeded
Informational
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
sunHwTrapSensorCritThresholdExceeded
Lower critical threshold exceeded
Major
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
sunHwTrapSensorCritThresholdDeasserted
Lower critical threshold no longer exceeded
Informational
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
sunHwTrapVoltageFatalThresholdExceeded
Lower fatal threshold exceeded
Critical
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
sunHwTrapVoltageFatalThresholdDeasserted
Lower fatal threshold no longer exceeded
Informational
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
sunHwTrapVoltageCritThresholdExceeded
Upper critical threshold exceeded
Critical
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
sunHwTrapVoltageCritThresholdDeasserted
Upper critical threshold no longer exceeded
Informational
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
sunHwTrapVoltageNonCritThresholdExceeded
Upper noncritical threshold exceeded
Minor
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
sunHwTrapVoltageOk
Upper noncritical threshold no longer exceeded
Informational
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM