Install a Fan Cable Assembly

  1. Slide the new cable through the opening in the chassis where the failed cable was previously installed.
    image:Illustration that shows where to install the fan cable in the                             chassis.
  2. Insert the four panel mount connectors through each of the receiving tabs and slide the black tab to the left to secure it.
    image:Illustration that shows how to insert the panel mount                             connectors.
  3. Screw the top bracket of the cable assembly to the chassis.
    image:Illustration that shows how to secure the top bracket of the cable                             assembly.
  4. Reinstall the interconnects in the same slots from which you removed them.

    See Servicing Internal Interconnect Assemblies, Servicing External Interconnect Assemblies (SPARC M7-16), and Servicing SP Internal Interconnect Assemblies.

  5. Reseat the SP tray.

    See Reseat or Install an SP Tray.

  6. Reseat the CMIOUs.

    See Reseat a CMIOU.

  7. Reinstall the fans in the same slots from which you removed them.

    See Install a Fan Module (CMIOU Chassis) or Install a Fan Module (Switch Chassis).

  8. Switch on the appropriate PDU circuit breakers and power on the server.

    Returning the Server to Operation.

  9. Verify that the fault has been cleared and the replaced component is operational.

    See Verify That a Fault Has Been Cleared.

  10. Return the replaced component to Oracle.

    See Prepare a Component for Return to Oracle.