Sun Netra T5440 Server

Exit Print View

Updated: September 2015
 
 

Remove the Server From the Rack

Remove the server from the rack prior to performing cold-swappable FRU replacement procedures except the FB-DIMMs, PCI cards, and the service processor.


Caution

Caution  - The server weighs approximately 80 lb (36 kg). Two people are required to dismount and carry the chassis.


  1. Disconnect all the cables and power cords from the server.
  2. From the front of the server, release the slide rail latches or remove the necessary hardmount screws, depending on you rack type.
  3. Set the server on a sturdy work surface.

    Caution

    Caution  - Do not attempt to open the front bezel while the bezel is resting on a flat surface. Doing so results in damage to the bezel hinges on either side.


  4. Perform antistatic measures.

    See Perform Antistatic Measures.