Install the Power Board

  1. Remove the replacement power board from its packaging and place it on an antistatic mat.
  2. Lower the power board into the chassis, aligning the board's holes with the standoffs in the chassis.
  3. Install the screws firmly to secure the power board to the chassis.
  4. Perform the installation instructions in the following sections:
  5. See Returning the Server to Operation to perform the tasks needed to bring the server back online.

    Note - After replacing the power distribution board and powering on the system, you must run the ALOM CMT setcsn and setcpn commands to set the electronically readable chassis serial number and server part number.
  6. At the ALOM CMT command line interface, use the setcsn command to set the chassis serial number and the setcpn command to set the server part number on the power distribution board.

    Caution

    Caution  - When performing the following steps, use special care to enter the correct numbers. Once the power distribution board has been programmed with a chassis serial number or server part number, the number cannot be changed.


    sc> setsc sc_servicemode true
    Warning: misuse of this mode may invalidate your warranty.
    sc> setcsn -c chassis_serial_number
    Are you sure you want to permanently set the Chassis Serial Number
    to chassis_serial_number [y/n]? y
    setcsn: Chassis serial number recorded.
    sc> setcpn -p chassis_part_number
    Are you sure you want to permanently set the Chassis Part Number
    to chassis_part_number [y/n]? y
    setcpn: Chassis part number recorded.
    sc> showplatform
    Sun-Netra-T5440
    Chassis Serial Number: chassis_serial_number
    Domain Status
    ------ ------
    SO Running
    sc> setsc sc_servicemode false