Remove the Left LED Indicator Module

  1. Prepare the server for service.
    1. Power off the server and disconnect the power cords from the power supplies.

      See Powering Down the Server.

    2. Extend the server into the maintenance position.

      See Extend the Server to the Maintenance Position.

    3. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

      See Take Antistatic Measures.

    4. Remove the server top cover.

      See Remove the Server Top Cover.

  2. Depending on your server's storage drive configuration, do one of the following:
    • If your server is configured with twelve 3.5-inch storage drives or twenty-four 2.5-inch storage drives, perform the following procedures.
      1. Remove the server fan assembly door.

        See Remove the Fan Assembly Door From the Server.

      2. Remove the four remaining No. 2 Phillips screws (two on each side of the chassis) that secure the disk cage assembly to the server chassis.
        image:Figure showing the removal of the disk cage                                                 assembly screws.
    • If your server is configured with eight 2.5-inch storage drives, remove the server disk cage cover.

      See Remove the Disk Cage Cover From the Server.

  3. Remove the fan modules from the server.

    See Remove a Fan Module.

  4. Disconnect all cables from the front storage drive backplane.

    See the procedures for your storage drive configuration in Servicing the Front and Rear Storage Drive Backplanes (FRU).

  5. Disconnect the left LED indicator module cable and the right LED/USB indicator module cable from the motherboard [1 and 2].
    image:Figure showing the removal of the disk cage assembly from the                                 server chassis.
  6. Slide the disk cage assembly forward, and then gently lift the disk cage assembly from the chassis [3].

    Set the disk cage assembly on an anti-static mat.

  7. Remove the left LED indicator module.
    1. Remove the two No. 2 Phillips screws that secure the LED indicator module to the server front panel [1].

      If present, remove the capping tape that secures the cable to the side of the disk cage assembly.


      image:Figure showing the removal of the left LED indicator                                         module.
    2. Remove the LED indicator module from the server front panel [2].