Oracle ILOM Legacy Targets for Voltage
This table lists voltage sensors. An out-of-range value might indicate a faulted
component. See Oracle ILOM Legacy Target Replaceable Components or Faulted Item Replaceable Components for a
link to the service task for that component.
|
|
|
|
Line voltage into PS 0
|
/SYS/PS0/V_IN
|
100 to 252 volts
|
Power source or power cord
|
Line voltage into PS 1
|
/SYS/PS1/V_IN
|
100 to 252 volts
|
Power source or power cord
|
Main board 1.0 VDC
|
/SYS/MB/V_+1V0
|
0.931 to 1.058 volts
|
Switch
|
Main board 1.2 VDC
|
/SYS/MB/V_+1V2
|
1.127 to 1.274 volts
|
Switch
|
Main board 1.5 VDC
|
/SYS/MB/V_+1V5
|
1.352 to 1.646 volts
|
Switch
|
Main board 1.8 VDC
|
/SYS/MB/V_+1V8
|
1.686 to 1.911 volts
|
Switch
|
Main board 2.5 VDC
|
/SYS/MB/V_+2V5
|
2.359 to 2.652 volts
|
Switch
|
Main board 3.3 VDC
|
/SYS/MB/V_+3V3
|
3.120 to 3.490 volts
|
Switch
|
Main board HCA 0.85 VDC
|
/SYS/MB/V_+0V85_HCA
|
0.823 to 0.931 volts
|
Switch
|
Main board HCA 1.05 VDC
|
/SYS/MB/V_+1V05_HCA
|
1.000 to 1.127 volts
|
Switch
|
Main board IB switch chip 0.85 VDC
|
/SYS/MB/V_+0V85_IBSW
|
0.823 to 0.931 volts
|
Switch
|
Main board IB switch chip 1.05 VDC
|
/SYS/MB/V_+1V05_IBSW
|
1.000 to 1.127 volts
|
Switch
|
Main board MBOM 3.3 VDC
|
/SYS/MB/V_+3V3_MBOMA
|
3.120 to 3.490 volts
|
Switch
|
Main board Standby 3.3 VDC
|
/SYS/MB/V_+3V3_STDBY
|
3.120 to 3.490 volts
|
Switch
|
RTC backup battery
|
/SYS/MB/V_VBAT
|
> 2.548 volts
|
Battery
|
SP 1.0 VDC
|
/SYS/SP/V_+1V0
|
0.872 to 1.117 volts
|
Switch
|
SP 1.5 VDC
|
/SYS/SP/V_+1V5
|
1.352 to 1.646 volts
|
Switch
|
SP 1.8 VDC
|
/SYS/SP/V_+1V8
|
1.578 to 2.009 volts
|
Switch
|
SP 3.3 VDC
|
/SYS/SP/V_+3V3
|
2.944 to 3.685 volts
|
Switch
|
Supplied voltage out of PS 0
|
/SYS/PS0/V_OUT
|
10 to 14 volts
|
Power supply 0
|
Supplied voltage out of PS 1
|
/SYS/PS1/V_OUT
|
10 to 14 volts
|
Power supply 1
|
|