Display the General Health of Components and Systems

  1. Access the Oracle ILOM CLI.

    See Accessing the SP.

  2. Display the health of the switch components.
    -> show /System -t health
    Target                                       | Property  | Value
    ---------------------------------------------+-----------+-------
    /System                                      | health    | OK
    /System/Power                                | health    | OK
    /System/Power/Power_Supplies/Power_Supply_0  | health    | OK
    /System/Power/Power_Supplies/Power_Supply_1  | health    | OK
    /System/Cooling                              | health    | OK
    /System/Cooling/Fans/Fan_0                   | health    | OK
    /System/Cooling/Fans/Fan_1                   | health    | OK
    /System/Cooling/Fans/Fan_2                   | health    | OK
    /System/Cooling/Fans/Fan_3                   | health    | OK
    /System/Cooling/Fans/Fan_4                   | health    | OK
    /System/Cooling/Fans/Fan_5                   | health    | OK
    /System/Cooling/Fans/Fan_6                   | health    | OK
    /System/Cooling/Fans/Fan_7                   | health    | OK
    /System/Networking                           | health    | OK
    /System/Networking/Switches/Switch_0         | health    | OK
    /System/Networking/Switches/Switch_1         | health    | OK
    ->
  3. In the output, identify the health state from the value column.

    See Oracle ILOM Target Health States.

    Use this table to help identify unhealthy components.

    Target
    Component
    /System
    Switch
    /System/Cooling
    Fan elements
    /System/Networking
    Switch chips
    /System/Power
    Power supplies
  4. Consider your next step.